74LVC1G57-Q100
Nexperia
Low-power configurable multiple function gate
13. Transfer characteristics
Table 12. Transfer characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
40 C to +85 C
Min Max
Typ[1]
40 C to +125 C Unit
Min Max
VT+
VT
VH
positive-going
threshold voltage Figure 14 and Figure 15
see Figure 12, Figure 13,
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
0.70
1.11
1.50
2.16
2.61
1.02
1.20
1.60
2.00
2.74
3.33
0.67
1.20
V
V
V
V
V
1.42
1.79
2.52
2.99
1.08
1.47
2.13
2.58
1.60
2.00
2.74
3.33
negative-going
threshold voltage Figure 14 and Figure 15
see Figure 12, Figure 13,
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
0.30
0.58
0.80
1.21
1.45
0.53
0.77
1.04
1.55
1.86
0.72
1.00
1.30
1.90
2.29
0.30
0.58
0.80
1.21
1.45
0.75
1.03
1.33
1.93
2.32
V
V
V
V
V
hysteresis voltage (VT+ VT);
see Figure 12, Figure 13,
Figure 14 and Figure 15
VCC = 1.8 V
VCC = 2.3 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 5.5 V
0.30
0.40
0.50
0.71
0.71
0.48
0.64
0.75
0.97
1.13
0.62
0.80
1.00
1.20
1.40
0.23
0.34
0.44
0.65
0.65
0.62
0.80
1.00
1.20
1.40
V
V
V
V
V
[1] Typical values are measured at Tamb = 25 C.
14. Waveforms transfer characteristics
9
7ꢈ
9
2
9
,
9
+
9
7ꢉ
9
2
9
,
PQDꢊꢀꢃ
9
+
9
9
7ꢈ
7ꢉ
PQDꢊꢀꢉ
VT+ and VT limits are at 70 % and 20 %.
Fig 12. Transfer characteristic
Fig 13. Definition of VT+, VT and VH
74LVC1G57_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet