■AEC-Q200 Murata Standard Specification and Test Methods
No
AEC-Q200 Test Item
Specifications.
AEC-Q200 Test Method
20 Capacitance Temperature
Characteristics
R6 : Within +/-15%
The capacitance change should be measured after 5 minutes
at each specified temperature stage.
ꢀꢀꢀ(-55℃ to +85℃)
Capacitance value as a reference is the value in step 3.
C8 : Within +/-22%
Step
Temperature(C)
Reference Temp.+/-2
Min. Operating Temp.+/-3
Reference Temp.+/-2
Max. Operating Temp.+/-3
Reference Temp.+/-2
ꢀꢀꢀ(-55℃ to +105℃)
1
2
3
4
5
・ Initial measurement
Perform a heat treatment at 150+0/-10 ℃ for 1hour and then sit
for 24+/-2 hours at room temperature. Perform the initial measurement.
Derating conditions on voltage and temperature (For Rated Voltage 100Vdc max.)
Derated products*1 are suitable for use in circuits w here continuous
applied voltage and temperature to the capacitor is derated (below
rated voltage and temperature).
A reliability assurance level equivalent to standard products*2 can be
secured by restricting the voltage and temperature according to the
derating conditions in the chart.
*1 Derated Products: The test voltage of these products is less than
150% of the rated voltage in the Durability / Operational Life Test.
*2 Standard Products: The test voltage of these products is 150% of
the rated voltage and over in the Durability / Operational Life Test.
JEMCGS-01744N