欢迎访问ic37.com |
会员登录 免费注册
发布采购

MT9075BP 参数 Datasheet PDF下载

MT9075BP图片预览
型号: MT9075BP
PDF下载: 下载PDF文件 查看货源
内容描述: E1单芯片收发器 [E1 Single Chip Transceiver]
分类和应用: PC
文件页数/大小: 82 页 / 275 K
品牌: MITEL [ MITEL NETWORKS CORPORATION ]
 浏览型号MT9075BP的Datasheet PDF文件第50页浏览型号MT9075BP的Datasheet PDF文件第51页浏览型号MT9075BP的Datasheet PDF文件第52页浏览型号MT9075BP的Datasheet PDF文件第53页浏览型号MT9075BP的Datasheet PDF文件第55页浏览型号MT9075BP的Datasheet PDF文件第56页浏览型号MT9075BP的Datasheet PDF文件第57页浏览型号MT9075BP的Datasheet PDF文件第58页  
MT9075B  
Preliminary Information  
Per Time Slot Control Words (Pages 07H and 08H)  
The control functions described by Table 69 are repeated for each PCM-30 channel. Page 07H addresses 10H to  
1FH correspond to time slots 0 to 15, while page 08H addresses 10H to 1FH correspond to time slots 16 to 31.  
Page 07H Address:  
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10 11 12 13 14 15  
10 11 12 13 14 15  
10 11 12 13 14 15  
Equivalent PCM 30  
Timeslots  
Page 08H Address:  
Equivalent PCM 30 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31  
Timeslots  
Table 72 - Mapping to CEPT Channels  
(Page 07H and 08H)  
Bit  
Name  
Functional Description  
7
TXMSG  
(0)  
Transmit Message Mode. If one, the data from the corresponding  
address location of Tx message mode buffer is transmitted in the  
corresponding PCM 30 time slot. If zero, the data on DSTi is transmitted  
on the corresponding PCM 30 time slot. Tx message mode buffer are  
accessed from pages 0FH and 10H.  
6
5
4
3
ADI  
(0)  
Alternate Digit Inversion. If one, the corresponding transmit time slot  
data on DSTi has every second bit inverted, and the corresponding PCM  
30 receive time slot has every second bit inverted. If zero, this bit has no  
effect on channel data.  
RTSL  
(0)  
Remote Time Slot Loopback. If one, the corresponding PCM 30  
receive time slot is looped to the corresponding PCM 30 transmit time  
slot. This received time slot will also be present on DSTo. If zero, the  
loopback is disabled.  
LTSL  
(0)  
Local Time Slot Loopback. If one, the corresponding transmit time slot  
is looped to the corresponding receive time slot. This transmit time slot  
will also be present on the transmit PCM 30 stream. If zero, this loopback  
is disabled.  
TTST  
(0)  
Transmit Test. If one and control bit ADSEQ (page 02H, address 13H)  
is one, the A-law digital milliwatt will be transmitted in the corresponding  
PCM 30 time slot. When one and ADSEQ is zero, a Pseudo-Random Bit  
15  
Sequence (PRBS 2 -1) will be transmitted is the corresponding PCM 30  
time slot. More than one time slot may be activated at once. If zero,  
neither of these test signals will be connected to the corresponding time  
slot.  
2
RRST  
(0)  
Receive Test. If one and control bit ADSEQ (page 02H, address 13H) is  
one, the A-law digital milliwatt will be transmitted in the corresponding  
DSTo time slot. When one and ADSEQ is zero, a Pseudo Random Bit  
15  
Sequence (PRBS 2 -1) receiver will be connected to the corresponding  
time slot. This receiver circuit will synchronize to the transmit PRBS  
signal and perform a bit comparison of the two sequences. If zero,  
neither of these test signals will be connected to the corresponding time  
slot.  
1
0
---  
---  
Unused.  
Unused.  
Table 73 - Per Time Slot Control Word  
(Page 07H and 08H)  
54  
 复制成功!