DATA SHEET
MAS 35x9F
2
4.6.2.2. Serial (I S) Input Interface Characteristics (SDI, SDIB)
at T = T , V
, V
= 2.2 ... 3.6 V, f
= 18.432 MHz, Typ. values for T = 25 °C in P(L/M)QFP package
CRYSTAL A
A
SUPD SUPA
Limit Values
Symbol
Parameter
Pin Name
Unit
Test Conditions
Min.
Typ.
Max.
tSICLK
I2S clock input clock period
SI(B)C
325
ns
fS = 48 kHz Stereo,
32 bits per sample
(for demand mode see
Table 4–6)
tSIDS
I2S data setup time before
rising edge of clock (for
continuous data stream:
falling edge)
SI(B)C,
SI(B)D
50
ns
tSIDH
tSIIS
I2S data hold time
SI(B)D
50
50
ns
ns
I2S ident setup time before
rising edge of clock (for
continuous data stream:
falling edge)
SI(B)C,
SI(B)I
tSIIH
tbw
I2S ident hold time
Burst wait time
SI(B)I
50
ns
SI(B)C, SI(B)D 480
Table 4–6: Maximum allowed sample clock frequency in Demand Mode
f
(kHz)
f (MHz)
min. t
162
(ns)
SICLK
Sample
C
48, 32
44.1
6.144
5.6448
3.072
177
24, 16
22.05
12, 8
325
2.8224
1.536
354
651
11.025
1.4112
708
T
SICLK
H
SI(B)C
SI(B)I
L
H
L
H
L
SI(B)D
T
T
SIDH
SIDS
Fig. 4–21: Continuous data stream at serial input A or B. In this mode, the word strobe SI(B)I is not used and the
data are read at the falling edge of the clock (bit[2] in D0:346 is set).
Micronas
June 30, 2004; 6251-505-1DS
73