DATA SHEET
HAL855
3.4.1. Storage and Shelf Life
The permissible storage time (shelf life) of the sensors is unlimited, provided the sensors are stored at a maximum of
30 °C and a maximum of 85% relative humidity. At these conditions, no Dry Pack is required.
Solderability is guaranteed for one year from the date code on the package.
3.5. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Operating Conditions/Characteris-
tics” is not implied and may result in unpredictable behavior of the device and may reduce reliability and lifetime.
All voltages listed are referenced to ground (GND).
Symbol
VDD
Parameter
Pin No.
Min.
4.5
8
Typ.
5
Max.
5.5
Unit
V
Remarks
Supply Voltage
Battery Supply Voltage
1
1
VDD
12
18
V
TJ >125°C,
RP = 120 Ω
6
12
18
TJ <125°C,
RP = 120 Ω
VPull-up
IOUT
CP
Output Pull-up Voltage
Continuous Output Current
Protection Capacitance
Load Capacitance
3
3
5
12
V
3
−
−
20
mA
nF
nF
1,2
2,3
4.7
0.33
4.7
4.7
1000
100
CL
Note: Please contact Micronas application support or check available application notes in case of usage of the sen-
sor beyond recommended operating conditions.
Micronas
Nov. 26, 2008; DSH000149_003EN
21