CCU 3000, CCU 3000-I
CCU 3001, CCU 3001-I
0203H
Bit
Port 1 Data Register
Reset
Read
Write
7 to 0
0
Port 1 Data
Port 1 Data
0204H
Bit
Port 1 Direction Register
Reset
Read
Write
7 to 0
1
x
‘1’ = input, ‘0’ = output mode
0205H
Bit
Port 2 Data Register
Reset
Read
Write
7 to 0
0
Port 2 Data
Port 2 Data
0206H
Bit
Port 2 Direction Register
Reset
Read
Write
7 to 0
1
x
‘1’ = input, ‘0’ = output mode
0207H
Bit
Port 3 Data Register
Reset
Read
Write
7 to 0
0
Port 3 Data
Port 3 Data
0208H
Bit
Port 3 Direction Register
Reset
Read
Write
7 to 0
1
x
‘1’ = input, ‘0’ = output mode
0209H
Bit
Port 4 Data Register
Reset
Read
Write
7 to 1
0
x
x
x
0
Port 4 Data (bit 0 only)
Port 4 data (bit 0, only)
020AH
Bit
Port 5 Mode
Reset
Read
Write
7 to 6
5 to 0
x
x
x
x
Port 4 Data (bit 0 only)
‘1’ = port select mode, ‘0’ = port mode
MICRONAS INTERMETALL
39