4.6. Electrical Characteristics
All voltages refer to ground.
4.6.1. Absolute Maximum Ratings
Symbol
Parameter
Pin
–
Min.
0
Max.
65
Unit
°C
°C
V
T
A
Ambient Operating Temperature
Storage Temperature
Supply Voltage
T
–
–40
–0.5
–0.3 V
+125
6
S
V
1
SUP
I
V
Input Voltage
4, 6, 16,
13 to 25,
42 to 68
V
SUP
+0.3 V
–
P
max
Maximum Power Dissipation
–
–
500
mW
The total sum of all the sink currents of all ports together must not exceed 80 mA I
and 280 mA – I high at any
out
outlow
time. Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress rating only. Functional operation of the device at these or any other conditions beyond those indicated
in the “Recommended Operating Conditions/Characteristics” of this specification is not implied. Exposure to absolute
maximum ratings conditions for extended periods may affect device reliability.
4.6.2. Recommended Operating Conditions at T = 0 °C to 65°C
A
Symbol
Parameter
Pin
1
Min.
4.75
0.5
Typ.
Max.
5.25
8
Unit
V
V
Supply Voltage
Clock Frequency
–
–
SUP
CLK
f
3, 4
MHz
4.6.3. Recommended Crystal Characteristics at C
= C
= 22 pF; C
≤ 2 pF; C ≈13 pF
XTAL1
XTAL2
stray
L
Symbol
Parameter
Min.
–20
–
Typ.
–
Max.
+85
–
Unit
°C
T
A
Ambient Operating Temperature
f
p
Parallel Resonance Frequency
4–8
MHz
@ C = 13 pF
L
R
r
Series Resistance
–
–
40 [8MHz]
Ω
150 [4 MHz]
C
C
P
Shunt Capacitance
–
–
7.0
20
–
pF
fF
0
Motional Capacitance
Rated Drive Level
–
–
1
–
0.02
–
mW
dB
f / f
p
Spurious Frequency Attenuation
20
–
H
32
MICRONAS INTERMETALL