PIC12F635/PIC16F636/639
15.2 DC Characteristics: PIC12F635/PIC16F636-I (Industrial)
Standard Operating Conditions (unless otherwise stated)
DC CHARACTERISTICS
Operating temperature
-40°C ≤ TA ≤ +85°C for industrial
Conditions
Param
No.
Sym
Device Characteristics
Supply Current(1,2)
Min Typ† Max Units
VDD
Note
D010
IDD
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
11
18
16
28
μA
μA
μA
μA
μA
μA
μA
μA
mA
μA
μA
μA
μA
μA
mA
μA
μA
μA
μA
μA
mA
μA
μA
mA
μA
μA
mA
mA
mA
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
2.0
3.0
5.0
4.5
5.0
FOSC = 32.768 kHz
LP Oscillator mode
35
54
D011
D012
D013
D014
D015
D016
D017
D018
D019
140
220
380
260
420
0.8
240
380
550
360
650
1.1
FOSC = 1 MHz
XT Oscillator mode
FOSC = 4 MHz
XT Oscillator mode
130
215
360
220
375
0.65
8
220
360
520
340
550
1.0
FOSC = 1 MHz
EC Oscillator mode
FOSC = 4 MHz
EC Oscillator mode
20
FOSC = 31 kHz
LFINTOSC mode
16
40
31
65
340
500
0.8
450
700
1.2
FOSC = 4 MHz
HFINTOSC mode
410
700
1.30
230
400
0.63
2.6
2.6
650
950
1.65
400
680
1.1
FOSC = 8 MHz
HFINTOSC mode
FOSC = 4 MHz
EXTRC mode
3.25
3.25
FOSC = 20 MHz
HS Oscillator mode
†
Data in “Typ” column is at 5.0V, 25°C unless otherwise stated. These parameters are for design guidance
only and are not tested.
Note 1: The test conditions for all IDD measurements in Active Operation mode are: OSC1 = external square
wave, from rail-to-rail; all I/O pins tri-stated, pulled to VDD; MCLR = VDD; WDT disabled. MCU only, Analog
Front-End not included.
2: The supply current is mainly a function of the operating voltage and frequency. Other factors, such as I/O
pin loading and switching rate, oscillator type, internal code execution pattern and temperature, also have
an impact on the current consumption. MCU only, Analog Front-End not included.
3: The peripheral current is the sum of the base IDD or IPD and the additional current consumed when this
peripheral is enabled. The peripheral Δ current can be determined by subtracting the base IDD or IPD
current from this limit. Max values should be used when calculating total current consumption.
4: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is
measured with the part in Sleep mode, with all I/O pins in high-impedance state and tied to VDD.
© 2007 Microchip Technology Inc.
DS41232D-page 167