MX25L4006E
The RDP instruction is for releasing from Deep Power Down Mode.
(14) Read Identification (RDID)
The RDID instruction is for reading the manufacturer ID of 1-byte and followed by Device ID of 2-byte. The MXIC
Manufacturer ID is C2(hex), the memory type ID is 20(hex) as the first-byte device ID, and the individual device ID of
second-byte ID is as followings: 13(hex) for MX25L4006E.
The sequence is shown as Figure 25.
While Program/Erase operation is in progress, it will not decode the RDID instruction, so there's no effect on the cy-
cle of program/erase operation which is currently in progress. When CS# goes high, the device is at standby stage.
(15) Read Electronic Manufacturer ID & Device ID (REMS)
The REMS instruction is an alternative to the Release from Power-down/Device ID instruction that provides both the
JEDEC assigned manufacturer ID and the specific device ID.
The REMS instruction is very similar to the Release from Power-down/Device ID instruction. The instruction is initi-
ated by driving the CS# pin low and shift the instruction code "90h" followed by two dummy bytes and one bytes
address (A7~A0). After which, the Manufacturer ID for MXIC (C2h) and the Device ID are shifted out on the falling
edge of SCLK with most significant bit (MSB) first as shown in Figure 26. The Device ID values are listed in Table 5.
ID Definitions. If the one-byte address is initially set to 01h, then the device ID will be read first and then followed by
the Manufacturer ID. The Manufacturer and Device IDs can be read continuously, alternating from one to the other.
The instruction is completed by driving CS# high.
Table 5. ID Definitions
Command Type
MX25L4006E
memory type
20
manufacturer ID
C2
memory density
13
RDID Command
electronic ID
12
RES Command
manufacturer ID
C2
device ID
12
REMS Command
P/N: PM1576
REV. 1.3, FEB. 10, 2012
18