NOTE: All part numbers
are RoHS Compliant
AMP M Series
Pin and Socket Connectors
Protective Hardware (Continued)
Shields,Two-Piece,
45° and 30° Cable Exit
A
Assembled
Material and Finish
Shields and Cable Clamps -
Steel, nickel plated
Screws - Steel, zinc plated
C
These Two-Piece Shields are
used to protect connectors
from dust, dirt and physical
damage and to provide strain
relief for the contacts. They
feature integral cable clamps
formed at 45° and are specif-
ically designed for use with
104 CF and 160 CF position
standard connectors; 30° exit
shield is available for 29 CF
position connectors.
B
These Shields may be used
with Pin Hoods to provide
pin protection.
45° Cable Exit
Note: A typical 45° Cable Exit Shield is illustrated. Slight differences in configuration exist between sizes.
These Two-Piece Shields may
be secured to a connector
housing using other appropri-
ate hardware such as Guide
Pins and Sockets.
Two-Piece Shields, 45° Cable Exit
Connectors Used On
(No. of Positions)
Max.
Cable
Dia.
Tyco Electronics does NOT
recommend the use of
shields with posted connec-
tors because of the potential
of shorting.
Dimensions
B
Shield Part No.
A
C
Standard
2.375
60.33
1.000
25.4
202169-4
202110-1
202798-1
1.145
29.08
2.845
72.26
104 CF
1.875
47.63
.650
16.51
1.845
46.86
2.770
70.36
2.750
69.85
1.200
30.48
160 CF
Note: All parts are packaged unassembled.
Two-Piece Shield, 30° Cable Exit
Connectors Used On
(No. of Positions)
Max.
Cable
Dia.
Dimensions
Shield Part No.
A
B
C
Standard
1.375
34.93
2.685
68.19
3.440
87.38
1.250
31.75
202483-3
29 CF
87
Catalog 82003
Revised 06-08
Dimensions are in millimeters
and inches unless otherwise
specified. Values in brackets are
Dimensions are shown for USA: 1-800-522-6752
reference purposes only. Canada: 1-905-470-4425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
Specifications subject
Mexico: 01-800-733-8926
www.tycoelectronics.com equivalent U.S. Customary Units. to change.
C. America: 52-55-5-729-0425 UK: 44-141-810-8967