Data Sheet
GE
CP2000AC54TE CPL High Efficiency Rectifier
100-120/200-277VAC input; Default Outputs: ±54VDC @ 2000W, 5VDC @ 4W
Table 3: Signal Definitions
All hardware alarm signals (Fault, PFW, OTW, Power Capacity) are open drain FETs. These signals need to be pulled HI to either 3.3V or 5V.
Maximum sink current 5mA. An active LO signal (< 0.4VDC) state. All signals are referenced to Logic_GRD unless otherwise stated.
Function
Output Enable
Label
Type
Input If shorted to Logic_GRD main output is ON in Analog or PMBus mode.
Output
Description
Enable
PFW
Power Fail Warning
I2C Interrupt
An open drain FET; Changes to LO 5msec before the output decays below 40VDC
.
Alert#_0/Alert#_1
Fault
Output This signal is pulled to 3.3V via a 10kꢀ resistor. Active LO.
Rectifier Fault
Module Present
ON/OFF
Output An open drain FET; normally HI, changes to LO.
MOD_PRES
ON/OFF
Output Short pin, see Status and Control description for further information on this signal.
Input Short pin, controls main output during hot-insertion and extraction. Ref: Vout ( - )
Input Selects operational mode. Ref: Vout ( - ). No-connect PMBus, 10kΩ - RS485
Input Changes the default set point of the main output.
Output Open drain FET; normally HI, changes to LO 5°C prior to thermal shutdown.
Output Open drain FET; HI indicates 2000W operation and LO indicates 1200W operation.
Input Voltage level addressing of Rectifiers within a single shelf. Ref: Vout ( - ).
Input Voltage level addressing of Rectifiers within multiple shelves. Ref: Vout ( - ).
Bi-direct Used to back bias the DSP from operating Rectifiers. Ref: Vout ( - ).
Input Resets the internal PCA9541 multiplexer
Protocol select
Margining
Protocol
Margin
Over-Temperature Warning OTW
Power Capacity
Rectifier address
Shelf Address
Back bias
POWER_CAP
Unit_addr
Shelf_addr
8V_INT
Reset
Mux Reset
Standby power
Current Share
I2C Line 0
5VA
Output 5V at 0.75A provided for external use
Ishare
Bi-direct A single wire active-current-share interconnect between modules Ref: Vout ( - ).
Input PMBus line 0.
SCL_0
I2C Line 0
SDA_0
Bi-direct PMBus line 0.
I2C Line 1
SCL_1
Input PMBus line 1.
I2C Line 1
SDA_1
Bi-direct PMBus line 1.
SMBALERT# Line 0
SMBALERT# Line 1
RS485 Line
ALERT#_0
ALERT#_1
RS_485+
RS_485-
Output PMBus line 0 interrupt
Output PMBus line 1 interrupt
Bi-direct RS485 line +
RS485 Line
Bi-direct RS485 line -
August 16, 2013
©2013 General Electric Company. All rights reserved.
Page 18