27 | Keysight | CX3300 Series Device Current Waveform Analyzer - Data Sheet  
Table 27. CX1103A characteristics overview  
Maximum bandwidth  
(-3 dB) 2  
Range  
RIN  
Noise (rms) 1  
DC offset range and resolution  
20 mA  
2 mA  
5 μA  
1.5 μA  
150 nA  
25 nA  
200 MHz  
75 MHz  
9 MHz  
±20 mA  
0.8 μA resolution  
50 Ω typ, 55 Ω max  
(50 Ω input ON)  
200 μA  
20 μA  
2 μA  
Current  
measurement  
±200 μA  
8 nA resolution  
2.5 MHz  
250 kHz  
100 kHz  
4 Ω typ, 6 Ω max  
(50 Ω input OFF)  
1.5 nA  
150 pA  
±2 μA  
80 pA resolution  
200 nA  
1. 20 MHz noise bandwidth measured with mainframe.  
2. Standalone bandwidth. The effective measurement bandwidth when connected to mainframe can be estimated by the following equation.  
1
BWeffective  
=
1
1
BWmainframe  
BWsensor  
2
2
+
Table 28. CX1103A DC measurement accuracy 1  
Standalone  
23 ±5 ºC  
With mainframe  
Range  
23 ±5 ºC  
TUSERCAL ±3 ºC, 24 hrs 2  
± (0.6% + 0.3%)  
± (0.6% + 0.4%)  
± (0.6% + 0.4%)  
± (0.6% + 0.4%)  
± (1.3% + 0.4%)  
± (1.3% + 0.3%)  
20 mA  
2 mA  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2% + 2%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
± (2.7% + 2.9%) **  
200 μA  
20 μA  
2 μA  
Gain [% of readings] + Offset [%  
of readings]  
200 nA  
1. Accuracy is defined at DC offset = 0 A. The “readings” means measured data by mainframe. DC measurement condition: 20 ms averaged.  
2. After executing the User Calibration with mainframe. Supplemental characteristics.  
Table 29. CX1103A other characteristics  
Rise time (10% to 90%)  
Measurable over range  
Burden voltage  
0.35 / Bandwidth [MHz]  
10% of range  
RIN * Measured current  
±0.5 V  
Input 50 Ω OFF  
Input 50 Ω ON  
Maximum input voltage (common mode) 1  
±1.0 V  
Absolute Maximum input current  
125 mA fuse protected  
1. All current measurement ranges.  
Table 30. CX1103A general information 1  
Cable length  
Dimension  
Weight  
Sensor cable: 1.5 m, Gnd lead: 16 cm  
45.8 mm (W), 28.1 mm (H), 163.1 mm (D)  
300 g  
1 each SMA(P) to BNC(J) 50 Ω Coaxial Adapter  
1 each GND lead  
Furnished accessories  
1. Refer to mainframe’s “Environmental and general” part for other information.  