35 | Keysight | B1505A Power Device Analyzer/Curve Tracer - Data Sheet
Output terminal:
Output terminal:
Supplemental characteristics
High force and guard
High sense and guard
Low force
Low sense
(Ø4 mm jack (banana))
Protection:
HPSMU, GNDU, HCSMU Low Force
Power indicator:
LED turns yellow when AC power is
applied and turns green the module
selector is ready to use.
Status indicator:
Green LED lights to indicate the present
connection path of module selector;
Open, HCSMU, HPSMU, or HVSMU.
Maximum voltage/current:
For HPSMU port:
H-AC Guard (SHV connector)
L-AC Guard (SHV connector)
External DC bias voltage: ±3000 V
Frequency:
10 kHz to 1 MHz (150 Ω at 10 kHz)
Series capacitance: 110 nF ±5%
Input resistance: 100 kΩ ±1%
Leakage current: 10 pA at 200 V
N1261A-004 protection adapter
for GNDU
(SHV output)
Specifications
Input terminals:
Force/Sense (Triaxial)
Output terminals:
Force (SHV)
N1261A protection adapt-
er
Sense (SHV)
N1261A-001 protection adapter
for HPSMU
(triaxial output)
N1262A Resistor Box
N1262A-001 1 MΩ
resistor box
Specifications
Input terminals:
Force (Triaxial)
Sense (Triaxial)
Output terminals:
Force (Triaxial)
Sense (Triaxial)
±200 V/1 A
For HCSMU port:
±40 V/2 A, ±20 V/30 A
(Pulse width 1 ms, duty 1%)
For HVSMU:
Specifications
Input terminals:
HVSMU port, 1 ea. (HV triaxial)
Output terminals:
SHV connector, 1 ea.
Resistance: 1 MΩ ±5%
Maximum voltage: ±3000 V
Maximum power: 9 W
±3000 V/4 mA,
±1500 V/2.5 A, ±2200 V/1.1 A
1. Either the HPSMU or the MPSMU can be
connected to HPSMU port.
Supplemental characteristics
Leakage current:
For HPSMU:
10 pA at 200 V
For HCSMU:
Supplemental characteristics
Leakage current: 10 pA at 200 V
Supplemental characteristics
Leakage current:
10 pA at 100 V
N1261A-002 protection adapter
for GNDU
(BNC output)
100 pA at 10 V (High Force to Low
Force, High Sense to
Low Sense)
N1262A-002 100 kΩ
resistor box
For HVSMU:
Specifications
Input terminals:
Force/Sense (Triaxial)
Output terminals:
Force (BNC)
10 pA at 1500 V (humidity range: 20%
to 70% RH)
30 pA at 3000 V (humidity range: 20%
to 50% RH)
Specifications
Input terminals:
HVSMU port, 1 ea. (HV triaxial)
Output terminals:
SHV connector, 1 ea.
Resistance: 100 kΩ ±5%
Maximum voltage: ±3000 V
Maximum power: 6.4 W
Sense (BNC)
N1260A high voltage bias-
tee
N1261A-003 protection adapter
for HPSMU (HV triaxial output)
Specifications
Supplemental characteristics
Specifications
Input terminals1:
Force (Triaxial)
Input terminals:
Leakage current: 10 pA at 100 V
HVSMU port, 1 ea. (HV triaxial)
MFCMU port, 1 ea.
Sense (Triaxial)
(4 BNC, Hp, Hc, Lp, Hc)
Output terminals:
Force (HV triaxial)
Sense (HV triaxial)
1. Either the HPSMU or the MPSMU can be
connected to HPSMU port.