IS61LV5128
ISSI
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
Min.
2.4
Max.
Unit
V
VOH
VOL
VIH
VIL
ILI
Output HIGH Voltage
VCC = Min., IOH = –4.0 mA
VCC = Min., IOL = 8.0 mA
—
0.4
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage(1)
Input Leakage
—
V
2.0
VCC + 0.3
0.8
V
–0.3
V
GND ≤ VIN ≤ VCC
Com.
Ind.
–1
–5
1
5
µA
ILO
Output Leakage
GND ≤ VOUT ≤ VCC, Outputs Disabled Com.
–1
–5
1
5
µA
Ind.
Note:
1. VIL = –3.0V for pulse width less than 10 ns.
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
-10ns
Min.
-12ns
Min.
-15ns
Min.
Symbol Parameter
TestConditions
Max.
Max.
Max.
Unit
ICC
VccOperating
SupplyCurrent
VCC = Max., CE = VIL
IOUT = 0 mA, f = fMAX.
Com.
Ind.
—
—
145
155
—
—
135
145
—
—
125
135
mA
ISB
TTL Standby
Current
(TTLInputs)
VCC = Max.,
VIN = VIH or VIL
CE ≥ VIH, f = fMAX.
Com.
Ind.
—
—
70
80
—
—
60
70
—
—
50
60
mA
ISB1
ISB2
TTL Standby
Current
(TTLInputs)
VCC = Max.,
VIN = VIH or VIL
CE ≥ VIH, f = 0
Com.
Ind.
—
—
20
25
—
—
20
25
—
—
20
25
mA
mA
CMOSStandby
Current
(CMOSInputs)
VCC = Max.,
Com.
Ind.
—
—
10
15
—
—
10
15
—
—
10
15
CE
VIN ≥ VCC – 0.2V, or
VIN 0.2V, f = 0
≤ VCC – 0.2V,
≤
Note:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
4
Integrated Silicon Solution, Inc. — 1-800-379-4774
Rev. B
07/16/01