欢迎访问ic37.com |
会员登录 免费注册
发布采购

TE28F128J3C-150 参数 Datasheet PDF下载

TE28F128J3C-150图片预览
型号: TE28F128J3C-150
PDF下载: 下载PDF文件 查看货源
内容描述: 英特尔StrataFlash闪存( J3 ) [Intel StrataFlash Memory (J3)]
分类和应用: 闪存
文件页数/大小: 72 页 / 909 K
品牌: INTEL [ INTEL ]
 浏览型号TE28F128J3C-150的Datasheet PDF文件第43页浏览型号TE28F128J3C-150的Datasheet PDF文件第44页浏览型号TE28F128J3C-150的Datasheet PDF文件第45页浏览型号TE28F128J3C-150的Datasheet PDF文件第46页浏览型号TE28F128J3C-150的Datasheet PDF文件第48页浏览型号TE28F128J3C-150的Datasheet PDF文件第49页浏览型号TE28F128J3C-150的Datasheet PDF文件第50页浏览型号TE28F128J3C-150的Datasheet PDF文件第51页  
256-Mbit J3 (x8/x16)  
This two-step sequence of setup followed by execution ensures that block lock-bits are not  
accidentally cleared. An invalid Clear Block Lock-Bits command sequence will result in SR.4 and  
SR.5 being set. Also, a reliable clear block lock-bits operation can only occur when VCC and VPEN  
are valid. If a clear block lock-bits operation is attempted while VPEN VPENLK, SR.3 and SR.5  
will be set.  
If a clear block lock-bits operation is aborted due to VPEN or VCC transitioning out of valid range,  
block lock-bit values are left in an undetermined state. A repeat of clear block lock-bits is required  
to initialize block lock-bit contents to known values.  
13.3  
Protection Register Program  
The Intel StrataFlash® memory (J3) includes a 128-bit Protection Register (PR) that can be used to  
increase the security of a system design. For example, the number contained in the PR can be used  
to “mate” the flash component with other system components such as the CPU or ASIC, preventing  
device substitution.  
The 128-bits of the PR are divided into two 64-bit segments. One of the segments is programmed at  
the Intel factory with a unique 64-bit number, which is unalterable. The other segment is left blank  
for customer designers to program as desired. Once the customer segment is programmed, it can be  
locked to prevent further programming.  
13.3.1  
13.3.2  
Reading the Protection Register  
The Protection Register is read in the identification read mode. The device is switched to this mode  
by issuing the Read Identifier command (0x90). Once in this mode, read cycles from addresses  
shown in Table 8 or Table 21 retrieve the specified information. To return to read array mode, write  
the Read Array command (0xFF).  
Programming the Protection Register  
Protection Register bits are programmed using the two-cycle Protection Program command. The  
64-bit number is programmed 16 bits at a time for word-wide configuration and eight bits at a time  
for byte-wide configuration. First write the Protection Program Setup command, 0xC0. The next  
write to the device will latch in address and data and program the specified location. The allowable  
addresses are shown in Table 8 or Table 21. See Figure 26, “Protection Register Programming  
Flowchart” on page 67  
Any attempt to address Protection Program commands outside the defined PR address space will  
result in a Status Register error (SR.4 will be set). Attempting to program a locked PR segment will  
result in a Status Register error (SR.4 and SR.1 will be set).  
13.3.3  
Locking the Protection Register  
The user-programmable segment of the Protection Register is lockable by programming Bit 1 of  
the PLR to 0. Bit 0 of this location is programmed to 0 at the Intel factory to protect the unique  
device number. Bit 1 is set using the Protection Program command to program “0xFFFD” to the  
PLR. After these bits have been programmed, no further changes can be made to the values stored  
in the Protection Register. Protection Program commands to a locked section will result in a Status  
Register error (SR.4 and SR.1 will be set). PR lockout state is not reversible.  
Datasheet  
47  
 复制成功!