 浏览型号JS28F128P30T85的Datasheet PDF文件第62页浏览型号JS28F128P30T85的Datasheet PDF文件第63页浏览型号JS28F128P30T85的Datasheet PDF文件第64页浏览型号JS28F128P30T85的Datasheet PDF文件第65页浏览型号JS28F128P30T85的Datasheet PDF文件第67页浏览型号JS28F128P30T85的Datasheet PDF文件第68页浏览型号JS28F128P30T85的Datasheet PDF文件第69页浏览型号JS28F128P30T85的Datasheet PDF文件第70页  
1-Gbit P30 Family  
When a programming operation is executing, issuing the Program Suspend command requests the  
WSM to suspend the programming algorithm at predetermined points. The device continues to  
output Status Register data after the Program Suspend command is issued. Programming is  
suspended when Status Register bits SR[7,2] are set. Suspend latency is specified in Section 7.5,  
“Program and Erase Characteristics” on page 45.  
To read data from the device, the Read Array command must be issued. Read Array, Read Status  
Register, Read Device Identifier, CFI Query, and Program Resume are valid commands during a  
program suspend.  
During a program suspend, deasserting CE# places the device in standby, reducing active current.  
VPP must remain at its programming level, and WP# must remain unchanged while in program  
suspend. If RST# is asserted, the device is reset.  
11.5  
Program Resume  
The Resume command instructs the device to continue programming, and automatically clears  
Status Register bits SR[7,2]. This command can be written to any address. If error bits are set, the  
Status Register should be cleared before issuing the next instruction. RST# must remain deasserted  
(see Figure 41, “Program Suspend/Resume Flowchart” on page 86).  
11.6  
Program Protection  
When VPP = VIL, absolute hardware write protection is provided for all device blocks. If VPP is at  
or below VPPLK, programming operations halt and SR[3] is set indicating a VPP-level error. Block  
lock registers are not affected by the voltage level on VPP; they may still be programmed and read,  
even if VPP is less than VPPLK  
.
Figure 31.  
Example VPP Supply Connections  
VCC  
VCC  
VPP  
VCC  
VPP  
VCC  
VPP  
PROT #  
10K Ω  
Low-voltage Programming only  
Logic Control of Device Protection  
Factory Programming with VPP = VPPH  
Complete write/Erase Protection when VPP VPPLK  
VCC  
VCC  
VCC  
VCC  
VPP  
VPP=VPPH  
VPP  
Low Voltage Programming Only  
Full Device Protection Unavailable  
Low Voltage and Factory Programming  
April 2005  
66  
Intel StrataFlash® Embedded Memory (P30)  
Order Number: 306666, Revision: 001  
Datasheet  