Intel® IXP42X Product Line of Network Processors and IXC1100 Control Plane Processor
Table 63.
HPI-16 Simplex Write Accesses Values
Symbol
Parameter
Min. Max. Units
Notes
Valid time that address is asserted on the line. The address
is asserted at the same time as chip select.
Tadd_setup
11
3
45
4
Cycles
Cycles
1, 5, 6
Delay from chip select being active and the HDS1 data
strobe being active.
Tcs2hds1val
5, 6
Thds1_pulse Pulse width of the HDS1 data strobe.
Tdata_setup Data valid prior to the rising edge of the HDS1 data strobe.
Tdata_hold
4
4
4
5
5
Cycles
Cycles
Cycles
2, 4, 5
3, 5, 6
3, 6
Data valid after the rising edge of the HDS1 data strobe.
36
Time required between successive accesses on the
expansion interface.
Trecov
2
17
Cycles
4, 6
Notes:
1.
The address phase parameter (T1) must be set to a minimum value of 2. This value allows three T
clocks for the address phase. This setting is required to ensure that in the event of an HRDY, the Intel®
IXP42X Product Line and Intel® IXC1100 Control Plane processors has had sufficient time to
recognize the HRDY and hold the address phase for at least one clock pulse after the HRDY is de-
active.
2.
3.
The data setup phase parameter (T2) must be set to a minimum value of 2. This value allows three T
clocks for setup phase.
The data strobe phase parameter (T3) must be set to a minimum value of 1. This value allows two T
clocks for the data phase. This setting is required to ensure that in the event of an HRDY, the Intel®
IXP42X Product Line and Intel® IXC1100 Control Plane processors has had sufficient time to
recognize the HRDY and hold the data setup phase for at least one clock pulse after the HRDY is de-
active.
4.
5.
Setting the recovery phase parameter (T5) will adjust the duration between successive accesses on
the Expansion Bus interface.
HRDY can be asserted by the DSP at any point in the access. The interface will not leave states T1 or
T3 until HRDY is de-active.
6.
7.
One cycle is the period of the Expansion Bus clock.
Timing tests were performed with a 70-pF capacitor to ground.