Signal Description  
Table 2-7. Parallel Mode Hot Plug Signals – Interface A and B – 1 to 2 Slots (Sheet 4 of 4)  
Signal  
Type  
Description  
PAREQ_[4]#/  
I
Slot 2 PRESENT2#: Input signal (optional). Used in conjunction with  
HxPRSNT1_2# to indicate to the Intel® 6700PXH 64-bit PCI Hub whether  
an add-on card is installed in the second hot plug slot and its power  
requirements. This signal is directly connected to the present bits on the  
PCI/PCI-X add-on card.  
HAPRSNT2_2#  
PBREQ_[4]#/  
HBPRSNT2_2#  
Only used when in dual-slot parallel hot plug mode (HPx_SLOT[3:0] =  
1010).  
HAPWREN_1  
HBPWREN_1  
O
O
Slot 1 Power Enable: Connected to slot 1 on-board power controller to  
regulate current and voltage flow of the PCI slot.  
Only used when in one-slot-no-glue, single-slot parallel, or dual-slot parallel  
hot plug mode (HPx_SLOT[3:0] = 1111, 1001, or 1010).  
PAGNT_[3]#/  
HAPWREN_2  
Slot 2 Power Enable: Connected to slot 2 on-board power controller to  
regulate current and voltage flow of the PCI slot.  
Only used when in dual-slot parallel hot plug mode (HPx_SLOT[3:0] =  
1010).  
PBGNT_[3]#/  
HBPWREN_2  
PAIRQ_[14]#/  
I
I
Slot 1 Power Fault: Power controller fault indication for over-current /  
under-voltage condition for the first hot plug slot. When asserted, the Intel®  
6700PXH 64-bit PCI Hub, if enabled, immediately asserts reset to the slot  
and disconnects the PCI slot from the bus.  
HAPWRFLT_1#  
PBIRQ_[14]#/  
Only used when in one-slot-no-glue, single-slot parallel, or dual-slot parallel  
hot plug mode (HPx_SLOT[3:0] = 1111, 1001, or 1010).  
HBPWRFLT_1#  
PAIRQ_[13]#/  
HAPWRFLT_2#  
Hot Plug Parallel Mode only - (HxPWRFLT_2#): Power controller fault  
indication for over-current / under-voltage condition for the second hot plug  
slot. When asserted, the Intel® 6700PXH 64-bit PCI Hub, if enabled,  
immediately asserts reset to the slot and disconnects the slot from the bus.  
PBIRQ_[13]#/  
HBPWRFLT_2#  
Only used when in dual-slot parallel hot plug mode (HPx_SLOT[3:0] =  
1010).  
HPA_SLOT[3]/  
HAPWRLED1#  
O
O
O
O
Slot 1 Power LED: Output signal connected to the green power LED  
corresponding to the first hot plug slot.  
HPB_SLOT[3]/  
HBPWRLED1#  
Only used when in one-slot-no-glue, single-slot parallel, or dual-slot parallel  
hot plug mode (HPx_SLOT[3:0] = 1111, 1001, or 1010).  
HPA_SIC/  
HAPWRLED2#  
Slot 2 Power LED: Output signal connected to the power LED  
corresponding to the second hot plug slot, which is green in color.  
Only used when in dual-slot parallel hot plug mode (HPx_SLOT[3:0] =  
1010).  
HPB_SIC/  
HBPWRLED2#  
HPA_PRST#/  
HPA_RST1#  
Slot 1 Reset: This is the slot 1 reset in the parallel hot plug mode.  
Connected to the RST# pin of the first PCI hot plug slot.  
Only used when in one-slot-not-glue, single-slot or dual-slot parallel hot  
plug mode (HPx_SLOT[3:0] = 1111, 1001 or 1010).  
HPB_PRST#/  
HPB_RST1#  
HPA_RST2#  
HPB_RST2#  
Slot 2 Reset: This is the slot 2 reset in the parallel hot plug mode.  
Connected to the RST# pin of the second PCI hot plug slot.  
Only used when in dual-slot parallel hot plug mode (HPx_SLOT[3:0] =  
1010).  
Intel® 6700PXH 64-bit PCI Hub Datasheet  
27  