Table 9.
OCT Calibration Accuracy Specifications for Cyclone V Devices
Calibration accuracy for the calibrated on-chip series termination (RS OCT) and on-chip parallel termination (RT OCT) are applicable at the moment of calibration.
When process, voltage, and temperature (PVT) conditions change after calibration, the tolerance may change.
Symbol
Description
Condition (V)
Calibration Accuracy
–I7, –C7
Unit
–C6
–C8, –A7
25-Ω RS
Internal series termination with
calibration (25-Ω setting)
VCCIO = 3.0, 2.5, 1.8, 1.5,
1.2
±15
±15
±15
%
%
%
%
50-Ω RS
Internal series termination with
calibration (50-Ω setting)
VCCIO = 3.0, 2.5, 1.8, 1.5,
1.2
±15
±15
±15
±15
±15
±15
±15
±15
±15
34-Ω and 40-Ω RS
Internal series termination with
calibration (34-Ω and 40-Ω setting)
VCCIO = 1.5, 1.35, 1.25, 1.2
48-Ω, 60-Ω, and 80-Ω RS
Internal series termination with
calibration (48-Ω, 60-Ω, and 80-Ω
setting)
VCCIO = 1.2
50-Ω RT
Internal parallel termination with
calibration (50-Ω setting)
VCCIO = 2.5, 1.8, 1.5, 1.2
VCCIO = 1.5, 1.35, 1.25
–10 to +40
–10 to +40
–10 to +40
–10 to +40
–10 to +40
–10 to +40
%
%
20-Ω, 30-Ω, 40-Ω,60-Ω, and
120-Ω RT
Internal parallel termination with
calibration (20-Ω, 30-Ω, 40-Ω, 60-Ω,
and 120-Ω setting)
60-Ω and 120-Ω RT
25-Ω RS_left_shift
Internal parallel termination with
calibration (60-Ω and 120-Ω setting)
VCCIO = 1.2
–10 to +40
±15
–10 to +40
±15
–10 to +40
±15
%
%
Internal left shift series termination
with calibration (25-Ω RS_left_shift
setting)
VCCIO = 3.0, 2.5, 1.8, 1.5,
1.2
Cyclone V Device Datasheet
14