TC1796
Functional Description
I/O Sharing Unit
•
Interconnecting inputs and outputs from internal clocks, FPC, GTC, LTC, ports, and
MSC interface.
3.14.2
Functionality of LTCA2
One Local Timer Cells Area provides a set of Local Timer Cells.
•
64 Local Timer Cells (LTCs)
– Three basic operating modes (Timer, Capture and Compare) for 63 units.
– Special compare modes for one unit
– 16-bit data width
– fGPTA maximum resolution
– fGPTA/2 maximum input signal frequency
Data Sheet
62
V1.0, 2008-04