Functional Description
The different operating modes in relation to the timing recovery are illustrated in figure 11.
CLOCK MASTER
512 kbit/s
SIP
TYPE 1
TYPE 2
SLD
SSI
512 kHz
8 kHz
DCL
PEB 2085/86
FSC1
128 kbit/s
SDAX
SDAR
SCA FSC2
128 kbit/s
128 kHz
8 kHz
S
TE Mode, Timing Mode 0
CLOCK SLAVE
CLOCK MASTER
512 kbit/s
SIP
SIP
PEB 2085/86
PEB 2050/52/55
512 kHz
SCLK
DCL
FSC2 FSD
FSC1
SYP
CLK
4096 kHz
8 kHz
S
System Int.
LT-S Mode, Timing Mode 1
CLOCK MASTER
CLOCK SLAVE
512 kbit/s
SIP
SIP
PEB 2050/52/55
PEB 2085/86
512 kHz
SCLK
DCL
CLK
SYP
FSC1
FSD FSC2
4096 kHz
8 kHz
T
System Int.
CLOCK SLAVE
LT-T Mode, Timing Mode 1
CLOCK MASTER
256 kbit/s
IDP0
256 kbit/s
IDP1
PEB 2085/86
PEB 2091
512 kHz
DCL
FSC2
FSC1
8 kHz
S
U
NT Mode
ITS00844
Figure 11
Operating Modes of the ISAC®-S (IOM®-1)
Semiconductor Group
35