BTS7012-2EPA 参数 Datasheet PDF下载

BTS7012-2EPA图片预览
型号: BTS7012-2EPA
PDF下载: 下载PDF文件 查看货源
内容描述: [BTS7012-2EPA 是一款 12mΩ 智能双通道高侧电源开关,提供保护功能和诊断。该设备被集成到 SMART7 技术中。]
分类和应用: 开关电源开关
文件页数/大小: 63 页 / 1680 K
品牌: INFINEON [ Infineon ]
 浏览型号BTS7012-2EPA的Datasheet PDF文件第41页浏览型号BTS7012-2EPA的Datasheet PDF文件第42页浏览型号BTS7012-2EPA的Datasheet PDF文件第43页浏览型号BTS7012-2EPA的Datasheet PDF文件第44页浏览型号BTS7012-2EPA的Datasheet PDF文件第46页浏览型号BTS7012-2EPA的Datasheet PDF文件第47页浏览型号BTS7012-2EPA的Datasheet PDF文件第48页浏览型号BTS7012-2EPA的Datasheet PDF文件第49页  
BTS7012-2EPA  
PROFET™ +2 12V  
Diagnosis  
IIS  
IIS(OL)  
IIS(EN)  
IL  
IL(OL)  
Diagnosis_ OLON _adv .emf  
Figure 34 Current Sense Ratio in Open Load at ON condition  
9.2.2  
Fault Current (IIS(FAULT))  
As soon a protection event occurs, changing the value of the internal retry counter (see Chapter 8.3 for more  
details) from its reset state, a current IIS(FAULT) is provided by pin IS when DEN is set to “high” and the affected  
channel is selected. The following 3 situations may occur:  
If the channel is ON and the number of retries is lower than “nRETRY(CR) + nRETRY(CYC) * nRETRY(NT)”, the current  
IS(FAULT) is provided for a time tIS(FAULT)_D after the channel is allowed to restart, after which IIS = IL / kILIS (as  
I
shown in Figure 35). During a retry cycle (while timer tRETRY is running) the current IIS(FAULT) is provided each  
time the channel diagnosis is checked  
If the channel is ON and the number of retries is equal than “nRETRY(CR) + nRETRY(CYC) * nRETRY(NT)”, the current  
IIS(FAULT) is provided until the internal counter is reset (either by expiring of tDELAY(CR) time or by DEN pin  
pulse, as described in Chapter 8.3.1)  
If the channel is OFF and the internal counter is not in the reset state, the current IIS(FAULT) is provided each  
time the channel diagnosis is checked  
IN  
t
t
IL  
IL(OVL)  
In ter nal  
counter  
0
1
2
0
t
DEN  
tIS(FAUL T)_D  
IIS(FAUL T)  
t
IIS(FAUL T)  
IIS  
IL / kILIS  
t
Diagnosis_PROFET_IISFAULT_load.emf  
Figure 35 IIS(FAULT) at Load Switching  
Data Sheet  
45  
Rev. 1.10  
2020-12-14  