BTS7012-2EPA
PROFET™ +2 12V
Diagnosis
9
Diagnosis
For diagnosis purpose, the BTS7012-2EPA provides a combination of digital and analog signals at pin IS. These
signals are generically named SENSE and written IIS. In case of disabled diagnostic (DEN pin set to “low”), IS
pin becomes high impedance.
A sense resistor RSENSE must be connected between IS pin and module ground if the current sense diagnosis is
used. RSENSE value has to be higher than 820 Ω (or 400 Ω when a central Reverse Battery protection is present
on the battery feed) to limit the power losses in the sense circuitry. A typical value is RSENSE = 1.2 kΩ.
Due to the internal connection between IS pin and VS supply voltage, it is not recommended to connect the IS
pin to the sense current output of other devices, if they are supplied by a different battery feed.
See Figure 32 for details as an overview.
VS
Channel 1
Channel 0
T
Overtemperature
OUT1
Internal Counters
IS Pin Control
OUT0
Logic
INn
DEN
DSEL
IL / kILIS
MUX
+
IIS(FAULT)
VDS(OLOFF)
MUX
IIS(OLOFF)
MUX
IS
RSENSE
Diagnosis_PROFET_2CH.emf
Figure 32 Diagnosis Block Diagram
Data Sheet
42
Rev. 1.10
2020-12-14