IS61C632A
OPERATING RANGE
Range
Commercial
Ambient Temperature
VCC
0°C to +70°C
3.3V +10%, –5%
Industrial
–40°C to +85°C
3.3V +10%, –5%
DC ELECTRICAL CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
Test Conditions
IOH = –5.0 mA
IOL = 5.0 mA
Min.
2.4
Max.
—
Unit
V
VOH
VOL
VIH
VIL
ILI
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input Leakage Current
—
0.4
V
2.0
VCCQ + 0.3
0.8
V
–0.3
V
(2)
GND ≤ VIN ≤ VCCQ
Com.
Ind.
–5
–10
5
1-
µA
ILO
Output Leakage Current
GND ≤ VOUT ≤ VCCQ, OE = VIH Com.
–5
–10
5
10
µA
Ind.
POWER SUPPLY CHARACTERISTICS (Over Operating Range)
-4
-5
-6
-7
-8
Symbol Parameter
Test Conditions
Typ. Max
Typ. Max.
Typ. Max.
Typ. Max.
Typ. Max. Unit
ICC
AC Operating
Supply Current
Device Selected,
All Inputs = VIL or VIH
OE = VIH,
Com. 150 180
140 170
130 160
140 170
120 150
130 160
110 140 mA
120 150 µA
Ind.
—
—
—
—
Cycle Time
≥ tKC min.
ISB
Standby Current
Device Deselected,
VCC = Max.,
Com.
Ind.
15
—
45
—
15
—
45
—
15
20
45
50
15
20
45
50
15
20
45 mA
50 µA
All Inputs = VIH or VIL
CLK Cycle Time
≥ tKC min.
IZZ
Power-Down Mode ZZ = VCCQ, CLK Running
Current All Inputs GND + 0.2V
or VCC – 0.2V
Com.
Ind.
1
—
10
—
1
—
10
—
1
2
10
20
1
2
10
20
1
2
10 mA
20 mA
≤
≥
Note:
1. MODE pin has an internal pull-up. ZZ pin has an internal pull-down. These pins may be a No Connect, tied to GND, or tied to
VCCQ.
2. MODE pin should be tied to Vcc or GND. They exhibit ±10 µA maximum leakage current when tied to ≤ GND + 0.2V or ≥ Vcc –
0.2V.
6
Integrated Circuit Solution Inc.
SSR001-0B