iC-TW8 16-BIT SIN/COS INTERPOLATOR  
Serial Configuration Mode  
Jan 9, 2013 Page SC27/36  
commands (see Programmer’s Reference). This  
forces the internal Z gating signal onto OUTA (pin  
18), as shown following, where it can be observed  
using an oscilloscope.  
Digital Output Index Sensor  
In applications where the incremental sensor pro-  
duces multiple input cycles per revolution—such as  
optical and MR magnetic sensors—an index sensor  
must be connected to the ZERO inputs to qualify or  
“gate” the Z output to ensure one and only one Z  
output pulse per revolution. In this case, it is neces-  
sary to align the Z output pulse with the ZERO input  
signal and to program the desired length and syn-  
chronization of the Z output pulse using the design  
tool (see page 21).  
Internal Z pulse,  
once per input cycle  
ZERO+  
OUTZ  
Delay  
ZERO–  
OUTA  
Figure 25: Observing the Z Gating Signal  
1 Input Cycle  
Calibrate the Z signal path by incrementing  
MAIN_ZPOS (the zpos location within an input cy-  
cle) until the Z output is centered within the Z gat-  
ing signal, as shown in Figure 24. MAIN_ZPOS can  
be accessed using the GUI or by writing to the  
MAIN_ZPOS register in the CFG block in internal  
memory via the serial ports (see Programmer’s Ref-  
erence). Finally, disable Index Gating Test Mode in  
the Test Mode pane of the Settings tab in the GUI or  
reset the Enable Z Test Mode bit (ztest) in the  
RB_TEST1 register and then store the updated  
MAIN_ZPOS register value to EEPROM using a  
Write All command via one of the serial ports or the  
Write EEPROM button in the GUI.  
SIN  
COS  
360°  
Sensor  
Input  
Angle  
zpos  
0°  
Z Gating  
Signal  
In general, the synchronization of the index gating  
signal to the Sin and Cos input signals is fixed. It is  
determined by the physical alignment of the incre-  
mental and Z tracks on the encoder disc or wheel  
and the physical alignment of the incremental and  
index sensors to each other. Since these physical  
alignments cannot typically be easily adjusted, it is  
important that they be carefully controlled from unit  
to unit to allow interchangeability of encoder wheels  
and sensors in series production.  
OUTZ  
OUTA  
OUTB  
zwidth  
zpos  
Figure 24: Z Output With Digital Index Sensor  
First, connect a digital output index sensor to the iC-  
TW8 as explained on page 13. Then, in the Z Con-  
figuration tab of the design tool, set the Desired  
ZERO Threshold to 0, configure the remaining pa-  
rameters as required (see page 21), and load the  
complete CFG bock to the iC-TW8 using the GUI  
or serial port commands (see Programmer’s Refer-  
ence).  
To guarantee one and only one Z output pulse per  
revolution, the ZERO input signal from the index  
sensor must be at least as wide as the desired width  
of the Z output pulse and no longer than two input  
cycles minus the width of the Z output pulse under  
all operating conditions. Specifically,  
To calibrate zpos, it is necessary to observe both the  
Z output and the internal Z gating signal simultane-  
ously. To observe the internal gating signal, enable  
Index Gating Test Mode in the Test Mode pane of  
the Settings tab in the GUI or set the Enable Z Test  
Mode bit (ztest) in the RB_TEST1 register in the  
RB Block of internal memory using serial port  
zwidth[]indexwidth[]720zwidth[]  
where indexwidth[°] is the width of the index sensor  
signal in input cycle degrees.  
Copyright © 2011–2013 iC-Haus  
http://www.ichaus.com  