iC-TW8 16-BIT SIN/COS INTERPOLATOR  
Serial Configuration Mode  
Jan 9, 2013 Page SC26/36  
Calibrating the Z Signal Path  
No Index Sensor  
The Z signal path must be calibrated to generate a Z  
output pulse at the proper location within a sensor  
input cycle and that is properly synchronized to the  
AB outputs. The Z output is configured using the  
design tool, but the Z signal path must be calibrated  
manually, if required. When the post-AB divider is  
not used and the interpolation factor, inter, is an in-  
teger, once the Z signal path is calibrated, one and  
only one Z output pulse, aligned as desired with the  
A and B outputs, is produced per revolution. For  
example, if zwidth = 1 (edge), OUTA is high at  
zpos, and OUTB is low at zpos, the following output  
synchronization results.  
The simplest case is where no index sensor is used.  
This is useful in applications where the incremental  
sensor produces only one input cycle per revolution,  
such as with an on-axis analog Hall effect device. In  
this case, one Z output is produced for every input  
cycle and it is only necessary to program the desired  
location, length, and synchronization of the Z output  
pulse using the design tool (see page 21).  
1 Input Cycle  
SIN  
COS  
OUTA  
360°  
Sensor  
OUTB  
Input  
Angle  
OUTZ  
zpos  
Figure 22: ABZ Output Synchronization  
0°  
If the post-AB divider is used or the actual interpo-  
lation, inter, is not an integer (see page 18), the con-  
figured ABZ output synchronization is not main-  
tained at every Z output. See page 27 for infor-  
mation on using the Z output with the post-AB di-  
vider.  
OUTZ  
OUTA  
OUTB  
zwidth  
zpos  
Figure 23: Z Output with No Index Sensor  
In general, there are three cases, depending on the  
type of index sensor connected to the ZERO inputs  
of the iC-TW8:  
In the design tool Z Configuration tab, answer  
“Yes” to the “Use Index Sensor?” question even  
though the ZERO inputs are tied to AVDD and  
AVSS (see page 13) and set the Desired ZERO  
Threshold to 0. Configure the remaining parameters  
as required and load the complete CFG bock to the  
iC-TW8 using the GUI or serial port commands (see  
Programmer’s Reference).  
1. No index sensor.  
2. Digital output index sensor.  
3. Analog output index sensor.  
These three cases each are discussed separately fol-  
lowing.  