iC-MN 25-BIT NONIUS ENCODER  
WITH 3-CH. SAMPLING 13-BIT Sin/D INTERPOLATION  
Rev D1, Page 51/59  
STARTUP BEHAVIOR  
Figure 28 shows the startup behavior of iC-MN. After If an error occurs while the EEPROM data is being  
turning on the power supply (power-on reset) iC-MN read (a CRC error or communication error with the  
reads the configuration data from the EEPROM. If the EEPROM), the current readin process is canceled and  
data can be read without error, a timeout of 8 ms is restarted. Following a third failed attempt the readin  
allowed to elapse.  
procedure is ended and the internal iC-MN configura-  
tion registers (addresses 0x00 to 0x4D) initialized with  
If the multiturn interface has been configured for an ex- a zero.  
ternal sensor, the device waits for a longer timeout of  
16 ms to elapse. The multiturn data is then read in and In doing so, NBISS = 0 selects for the BiSS C protocol  
the first conversion performed in order to determine the for the I/O interface enabling BiSS C register commu-  
absolute position (see page 47). iC-MN then goes into nication.  
normal operation.  
If an attempt to read sensor data is made iC-MN would  
reply an 8-bit zero value with set error and warning  
startup  
bits (sequence: start bit 1x high, position 8x zero, er-  
ror/warning 2x zero, CRC 6x high followed by zero bits  
read EEPROM  
(max 3 times on error)  
when the clock signal is continued).  
EEPROM ok?  
Following successful configuration using the I/O inter-  
face command SOFT_RES must be issued in order to  
switch iC-MN to normal operation (see page 42).  
serial-interface active  
for configuration  
(no sensor data request  
MODE_MT = 00  
possible)  
yes  
no  
8 ms timeout  
16 ms timeout  
via command SOFT_RES  
MODE_ST:  
sync_mode is  
nonius?  
yes  
no  
yes  
MODE_MT = 00  
no  
normal operation:  
ready for  
sensor data requests  
first conversion to get  
initial period information  
command execution  
multiturn-startup  
Figure 28: Startup behavior