型号: IBM0164165BT3C-60
PDF下载: 下载PDF文件 查看货源
内容描述: [EDO DRAM, 4MX16, 60ns, CMOS, PDSO50, 0.400 X 0.825 INCH, PLASTIC, TSOP2-50]
分类和应用: 动态存储器光电二极管内存集成电路
文件页数/大小: 28 页 / 480 K
品牌: IBM [ IBM ]
 浏览型号IBM0164165BT3C-60的Datasheet PDF文件第4页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第5页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第6页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第7页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第9页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第10页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第11页浏览型号IBM0164165BT3C-60的Datasheet PDF文件第12页  
Discontinued (8/98 - last order; 12/98 last ship)
IBM0164165B
IBM0164165P
4M x 16 13/9 EDO DRAM
Read Cycle
-50
Symbol
t
RAC
t
CAC
t
AA
t
OEA
t
RCS
t
RCH
t
RRH
t
RAL
t
CLZ
t
OEZ
t
CDD
t
OFF
t
OES
t
ORD
Parameter
Min.
Access Time from RAS
Access Time from CAS
Access Time from Address
Access Time From OE
Read Command Setup Time
Read Command Hold Time to CAS
Read Command Hold Time to RAS
Column Address to RAS Lead Time
CAS to Output in Low-Z
Output Buffer Turn-Off Delay From OE
CAS to D
IN
Delay Time
Output Buffer Turn-Off Delay
OE Setup Time Prior to CAS
OE Setup Time Prior to RAS (Hidden Refresh)
0
0
0
25
0
0
13
0
5
0
Max.
50
13
25
13
13
13
Min.
0
0
0
30
0
0
15
0
5
0
Max.
60
15
30
15
15
15
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
1
5
7
4
7
6
1, 2, 3, 5
1, 2, 5
1, 2, 5
-60
Units
Notes
1. In a Test Mode Read cycle, the value of t
RAC
, t
AA
, t
CAC
and t
CPA
are delayed by 5ns from the specified value. These parameters
must be adjusted in Test Mode cycles by adding 5ns to the specified value. Associated timings must also be adjusted by 5ns.
2. Operation within the t
RCD
(max.) limit ensures that t
RAC
(max.) can be met. t
RCD
(max.) is specified as a reference point only. If t
RCD
is greater than the specified t
RCD
(max.) limit, then access time is controlled by t
CAC
.
3. Operation within the t
RAD
(max.) limit ensures that t
RAC
(max.) can be met. t
RAD
(max.) is specified as a reference point only. If t
RAD
is
greater than the specified t
RAD
(max.) limit, then access time is controlled by t
AA
.
4. Either t
CDD
or t
OED
must be satisfied.
5. Measured with the specified current load and 100pF.
6. Either t
RCH
or t
RRH
must be satisfied for a read cycle.
7. t
OFF
(max.) and t
OEZ
(max.) define the time at which the output achieves the open circuit condition and are not referenced to output
voltage levels.
©IBM Corporation. All rights reserved.
Use is further subject to the provisions at the end of this document.
88H2012
GA14-4251-02
Revised 11/97
Page 8 of 28