RF42:
Parameter
VDD to GND
VDD to GND on
RF42/43
7. Description: Wake-up Timer and Low Duty Cycle Modes not functional.
Impacts: These features are not supported.
Workaround: Use the external microcontroller or the 32 kHz XTAL option on the RF22 to implement these
functions.
Resolution: Will be fixed in the next revision.
This document may contain preliminary information and is subject to change by
Hope Microelectronics without notice. Hope Microelectronics assumes no
HOPE MICROELECTRONICS CO.,LTD