RF42/43  
15. Errata Details  
1. Description: The TX current consumption at +13 dBm does not meet specification; lower power settings are  
within specification.  
Impact: May impact battery life. The +13 dBm current consumption is at 34 mA versus the data sheet  
specification of 28 mA.  
Workaround: No workaround exists in the current silicon for +13 dBm; lower power levels are unaffected.  
Resolution: Will be fixed in the next revision.  
2. Description: Some non-standard frequencies are not supported.  
Impacts: Operation in frequencies between 240-280 MHz and 480-560 MHz should be avoided.  
Workaround: These are non-standard bands and should result in no customer impact; no workaround at this  
time.  
Resolution: Will be fixed in the next revision.  
3. Description: Radio does not return to the low power state when in Auto TX mode.  
Impacts: When using Auto TX mode, the radio will not return to the low power state when the TX FIFO  
reaches the empty state.  
Workaround: The FIFO underflow interrupt can be enabled allowing the external MCU to wake up when the  
TX FIFO is empty and put the radio into the low power state: Program register 05h bit 7(enfferr =  
1).  
Resolution: Will be fixed in the next revision.  
4. Description: Potential modem failure in receive mode with default settings.  
Impacts: Under strong blocker conditions, the modem can fail unless the listed workaround is followed.  
Workaround: Operate the radio with AFC enabled: Program register 56h to C1h.  
Resolution: Will be fixed in the next revision.  
5.Description: Default register settings for optimal current consumption.  
Impacts: Current consumption.  
Workaround: Program register 57h bits 2:0 (cdcurr[2:0] = 001), register 59 bit 6 (fbdivhc = 0), register 5Ah bits  
1:0 (vcocur[1:0] = 01).  
Resolution: Will be fixed in the next revision.  
6. Description: Register modification required for TX data-rates greater than 100 kbps.  
Impacts: Eye closure and phase noise.  
Workaround: Program register 58h bits 7:6 (cpcurr[1:0] = 11).  
Resolution: Will update data sheet to reflect operation.  