HI-3110  
required in the usual way. While in this mode, any bus  
activity is ignored. Loopback is activated by programming  
the MODE<2:0> bits to <001> in the CTRL0 register.  
TRANSCEIVER  
The HI-3110 contains an integrated transceiver operating  
from 5V and the line driver is capable of maintaining a  
detectable signal for bus lengths well in excess of  
recommended CAN 2.0B standards. The digital logic and IO  
can be powered from 3.3V or 5V.  
MONITOR MODE  
Monitor mode (also known as listen-only or silent mode)  
allows the HI-3110 to monitor all bus activity without  
disturbing the bus. No messages or dominant bits (such as  
ACK or active error frame bits) are transmitted to the bus  
while in this mode. Also, the error counters are reset and  
deactivated. Messages from the bus are received in the  
same way as Normal Mode and messages that are not  
acknowledged by another node on the bus are ignored i.e.  
any frame containing an error will be ignored. Acceptance  
filters can be set up to reject or accept specific messages  
into the FIFO and all interrupt flags are set as required in the  
usual way. Monitor mode is activated by programming the  
MODE<2:0> bits to <010> in the CTRL0 register.  
PROTECTION FEATURES  
The BUS and SPLIT pins are protected against ESD to over  
4KV (HBM) and from shorts between -58V to +58V  
continuous, as specified in ISO 11898-5.  
In addition, a Permanent Dominant Timeout protection is  
implemented by means of an independent counter  
monitoring the dominant transmission state and  
automatically shutting off the transmission if it exceeds  
typically 2ms.  
SLEEP MODE  
MODES OF OPERATION  
The HI-3110 can be placed in a low power sleep mode if  
there is no bus activity and the transmit FIFO is empty. In  
this mode, the internal oscillator and all analog circuitry  
(transceiver) are off, drawing typically less than 20mA. Note  
that the SPI bus is active during sleep mode, so it is possible  
for the host to communicate with the HI-3110 while it is  
asleep (e.g. load transmit FIFOs). Sleep mode is exited by  
selecting an alternative mode of operation, or automatic  
wake up following bus activity can be enabled by setting the  
WAKEUP bit in the CTRL0 register - in this case a low power  
receiver monitors the bus for a detectable dominant bit..  
The device will wake up in Monitor Mode. Note that it will  
take a finite time for the oscillator and analog circuitry to  
come back on line. Since the internal oscillator takes a finite  
time to wake up, the message which caused the wake-up  
may not be stored.  
The HI-3110 supports five modes of operation, namely,  
Initialization Mode, Normal Mode, Loopback Mode, Monitor  
Mode and Sleep Mode.  
INITIALIZATION MODE  
Initialization mode is used to configure the device before  
normal operation. Bit timing registers and acceptance  
filters and masks can only be modified in this mode.  
Initialization mode is the default mode following RESET and  
can also be activated by programming the MODE<2:0> bits  
to <1xx> in the CTRL0 register. Switching to Initialization  
mode resets the receiver and transmitter. During  
initialization mode, the error counters are held reset.  
NORMALMODE  
Sleep mode is activated by programming the MODE<2:0>  
bits to <011> in the CTRL0 register. However, the actual  
mode change will only occur whenever the CAN bus is quiet.  
If the chip is transmitting, the mode change is delayed until  
the transmission is complete. If there is bus activity, the  
mode change is delayed until the receiver protocol control  
detects an inter-message gap.  
Normal mode is the standard operating mode of the HI-3110.  
In this mode, the HI-3110 can transmit, receive and  
acknowledge messages from the CAN bus, handling all  
aspects of the CAN protocol. Normal mode is activated by  
programming the MODE<2:0> bits to <000> in the CTRL0  
register.  
LOOPBACK MODE  
CAN PROTOCOLOVERVIEW  
Loopback mode is used for self-test. The transceiver digital  
input is fed back to the receiver without being transmitted to  
the bus. Messages are transmitted from the transmit FIFO  
in the usual way and received by the receive FIFO as if they  
were received from a remote node on the bus.  
The HI-3110 supports Standard, Extended and Remote  
Frames, as defined in the CAN specification IS0 11898-  
1:2003(E) (also known as CAN 2.0B).  
BIT ENCODING  
Acceptance filters can be set up to accept or reject specific  
messages into the FIFO and all interrupt flags are set as  
CAN frames are encoded according to the Non-Return-To-  
Zero (NRZ) method with bit stuffing. NRZ means that the  