欢迎访问ic37.com |
会员登录 免费注册
发布采购

HI-3111PCT 参数 Datasheet PDF下载

HI-3111PCT图片预览
型号: HI-3111PCT
PDF下载: 下载PDF文件 查看货源
内容描述: 航空电子与CAN收发器集成控制器 [Avionics CAN Controller with Integrated Transceiver]
分类和应用: 电子控制器航空
文件页数/大小: 53 页 / 178 K
品牌: HOLTIC [ HOLT INTEGRATED CIRCUITS ]
 浏览型号HI-3111PCT的Datasheet PDF文件第3页浏览型号HI-3111PCT的Datasheet PDF文件第4页浏览型号HI-3111PCT的Datasheet PDF文件第5页浏览型号HI-3111PCT的Datasheet PDF文件第6页浏览型号HI-3111PCT的Datasheet PDF文件第8页浏览型号HI-3111PCT的Datasheet PDF文件第9页浏览型号HI-3111PCT的Datasheet PDF文件第10页浏览型号HI-3111PCT的Datasheet PDF文件第11页  
HI-3110  
binary value of this 4-bit field specifies the number of data  
Notes: If the passive error flag is generated by a receiver, it  
cannot prevail over any other activity on the bus. Therefore,  
it must wait for 6 consecutive bits of equal polarity before  
completing the error flag. If the passive error flag is  
generated by a transmitter, the bit stuffing rule is violated and  
it will cause other nodes to generate error flags. Two  
exceptions to this rule are  
bytes in the data payload (0 - 8 bytes). Note: All binary  
combinations greater than or equal to <1 0 0 0> specify 8  
bytes of data.  
The remaining fields of the extended data frame (Data field,  
CRC field, acknowledge field, EOF field and IFS field) are  
constructed in the same way as the standard frame format.  
a) the passive error flag starts during arbitration and another  
node prevails and begins transmitting, and  
b) the error flag starts less than 6 bits before the end of the  
CRC sequence and the last bits of the CRC sequence all  
happen to be recessive.  
REMOTE FRAME  
The remote frame is shown in figure 4. The function of  
remote frames is to allow a receiver which periodically  
receives certain types of data to request that data from the  
transmitting source. The identifier of the remote frame must  
be identical to the identifier of the requested transmitting  
node’s data frame and the data length code (DLC) should be  
equal to the DLC of the requested data. Simultaneous  
transmission of remote frames with the same identifier  
and different DLCs will lead to unresolvable collisions  
OVERLOAD FRAME  
The overload frame is shown in figure 6. It has the same  
format as the active error frame, consisting of an overload  
flag field and an overload delimiter. The overload flag  
consists of 6 consecutive dominant bits. This condition  
violates the rule of bit-stuffing and causes all other nodes on  
the bus to generate echo flags, similar to the active error flag  
echos. Therefore, the overload flag field will consist of the  
superposition of different overload flags sent by individual  
nodes, resulting in a minimum of 6 and maximum of 12  
consecutive dominant bits. The overload flag is followed by  
the overload delimiter, consisting of 8 recessive bits.  
on the bus. For this reason, ARINC 825 strongly  
discourages the use of remote frames.  
The format of a remote frame is identical to the format of the  
corresponding data frame except the remote frame has no  
data payload. Remote frames and data frames are  
distinguished by a recessive RTR bit in the remote frame.  
This means if a receiver sends a remote frame and the  
sending node transmits at the same time, the sending node  
(with a dominant RTR bit) will win arbitration and the  
requesting node will receive the desired data immediately.  
An overload frame, unlike an error frame, can only be  
generated during the interframe space. There are two types  
of overload frame:  
1) Reactive Overload Frame, resulting from  
a) detection of a dominant bit during the first or second bit of  
intermission,  
ERROR FRAME  
The error frame is shown in figure 5. Any node detecting an  
error generates an error frame. The error frame consists of  
two fields, the error flag field and the error delimiter. The  
type of error flag field depends on the error status of the  
node, error-active or error-passive (see below). An error-  
active node generates an active error flag and an error-  
passive node generates a passive error flag.  
b) detection of a dominant bit at the last (seventh) bit of EOF  
in received frames, or  
c) detection of a dominant bit at the last (eighth) bit of an error  
delimiter or overload delimiter.  
The reactive overload frame is started one bit after detecting  
any of the above dominant bit conditions.  
2) Requested Overload Frame. A node which is unable to  
begin reception of the next message due to internal  
conditions may request a delay by transmitting a maximum  
of two consecutive overload frames. The requested  
overload frame must be started at the first bit of an expected  
intermission.  
Active Error Flag: An active error flag consists of 6  
consecutive dominant bits. This condition violates the rule  
of bit-stuffing and causes all other nodes on the bus to  
generate error flags, known as echo error flags. Therefore,  
the error flag field will consist of the superposition of different  
error flags sent by individual nodes, resulting in a minimum  
of 6 and maximum of 12 consecutive dominant bits. The  
error flag field is followed by the error delimiter, consisting of  
8 recessive bits.  
Note 1): The HI-3110 will never initiate an overload frame  
unless reacting to one of the conditions in case 1) above.  
Note 2): Initiation of overload frames is prohibited byARINC  
825 since they increase the network loading.  
Passive Error Flag: A passive error flag consists of 6  
recessive bits. This is followed by the 8 recessive bits of the  
error delimiter. Therefore, an error frame sent by an error-  
passive node consists of 14 consecutive recessive bits.  
Since this will not disturb the bus, a transmitting node will  
continue to transmit unless it detects the error itself, or  
another error-active node detects the error.  
HOLT INTEGRATED CIRCUITS  
7
 复制成功!