HMC1190LP6GE
v01.1112
BROADBAND HIGH IP3 DUAL CHANNEL DOWNCONVERTER
w/ Fractional-N PLL & VCO, 0.7 - 3.5 GHz
Harmonics of LO
MxN Spurious @ IF Port
nLO Spur @ RF Port
nLO
LO Freq. (GHz)
1
2
3
4
mRF
0
1
2
3
4
0.7
-65
-80
-59
-59
-60
-59
-60
-53
-45
-55
-58
-54
-59
-58
-58
-63
-67
-64
-65
-72
-73
-82
-77
-73
-63
-67
-62
-64
-63
-55
-48
-48
0
1
2
3
4
xx
-44
0
-52
-44
-72
-88
-88
-52
-17
-50
-71
-88
-55
-52
-80
-87
-87
1.1
-49
-87
-88
-85
-45
-62
-85
1.5
1.9
2.3
RF Freq. = 0.9 GHz @-5 dBm
LO Freq. = 0.8 GHz @ Max. level
All values in dBc below IF power level (1RF - 1LO).
2.7
3.1
3.5
LO = Max. level
All values in dBm measured at RF port.
MxN Spurious @ IF Port
MxN Spurious @ IF Port
nLO
nLO
mRF
0
1
2
3
4
mRF
0
1
2
3
4
0
1
2
3
4
xxx
-54
-83
-87
-83
-44
0
-49
-43
-76
-86
-85
-64
-28
-57
-88
-85
-49
-65
-84
-85
-87
0
1
2
3
4
xxx
-58
-80
-82
-84
-44
0
-47
-46
-75
-86
-85
-65
-40
-67
-83
-85
-53
-68
-85
-85
-87
-49
-72
-83
-60
-82
-82
RF Freq. = 1.9 GHz @-5 dBm
LO Freq. = 1.8 GHz @ Max. level
RF Freq. = 2.5 GHz @-5 dBm
LO Freq. = 2.4 GHz @Max. level
All values in dBc below IF power level (1RF - 1LO).
All values in dBc below IF power level (1RF - 1LO).
Truth Table [1]
CHIPEN
PLL/VCO
(V)
LOW
OFF
ON
HIGH
[1] IF and LO amplifiers can be disabled through SPI bus. See `Enabling/Disabling Mixer Features` application section.
For price, delivery and to place orders: Hittite Microwave Corporation, 2 Elizabeth Drive, Chelmsford, MA 01824
Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com
Application Support: Phone: 978-250-3343 or apps@hittite.com
19