Specifications HS-1840RH  
TABLE 4. POST 200K RAD(Si) ELECTRICAL CHARACTERISTICS  
Tested, per MIL-STD-883. Unless Otherwise Specified: V- = -15V, V+ = +15V, VREF = +5V, VAH = +4.5V, VAL = 0.5V  
LIMITS  
MIN MAX  
-1000 1000  
GROUP A  
SUBGROUPS TEMPERATURE  
PARAMETER  
SYMBOL  
CONDITIONS  
UNITS  
o
Input Leakage Current,  
Address, or Enable Pins  
IAH  
IAL  
Measure Inputs Sequentially,  
Ground All Unused Pins  
1
1
1
1
+25 C  
nA  
o
Leakage Current Into  
the Source Terminal of  
an “Off” Switch  
+IS(OFF)  
VS = +10V, All Unused Inputs  
and Output = -10V, VEN = 4.5V  
+25 C  
-100  
-100  
-100  
100  
100  
100  
nA  
nA  
nA  
o
-IS(OFF)  
VS = -10V, All Unused Inputs and  
Output = +10V, VEN = 4.5V  
+25 C  
o
Leakage Current into  
the Source Terminal of  
an “Off” Switch With  
Power “Off”  
+IS(OFF)  
Power Off  
V+, V-, VREF, A0, A1, A2, A3, A4,  
EN = GND, Unused Inputs Tied to  
GND, VS = +25V  
+25 C  
o
Leakage Current Into  
the Source Terminal of Overvoltage All Unused Inputs Tied to GND  
an “Off” Switch With  
+IS(OFF)  
VS = +25V, VD = 0V, VEN = 4.5V  
1
1
1
1
1
+25 C  
-1500 1500  
-1500 1500  
nA  
nA  
nA  
nA  
nA  
o
-IS(OFF)  
VS = -25V, VD = 0V, VEN = 4.5V  
+25 C  
Overvoltage Applied  
Overvoltage All Unused Inputs Tied to GND  
o
Leakage Current Into  
the Drain Terminal of  
an “Off” Switch  
+ID(OFF)  
-ID(OFF)  
+ID(OFF)  
VD = +10V, VEN = 4.5V  
All Unused Inputs = -10V  
+25 C  
-100  
-100  
100  
100  
o
VD = -10V, VEN = 4.5V  
All Unused Inputs = +10V  
+25 C  
o
Leakage Current Into  
the Drain Terminal of  
an “Off” Switch With  
Overvoltage Applied  
VS = +25V, Measure VD,  
+25 C  
-1000 1000  
-1000 1000  
Overvoltage VEN = 4.5V  
All Unused Inputs to GND  
o
-ID(OFF)  
VS = -25V, Measure VD,  
Overvoltage VEN = 4.5V  
All Unused Inputs to GND  
1
1
1
+25 C  
nA  
nA  
nA  
o
Leakage Current from  
an “On” Driver into the  
Switch (Drain & Source)  
+ID(ON)  
VS = +10V, VD = +10V,  
VEN = 0.5V  
All Unused Inputs = -10V  
+25 C  
-100  
-100  
100  
100  
o
-ID(ON)  
VS = -10V, VD = -10V,  
VEN = 0.5V  
+25 C  
All Unused Inputs = +10V  
o
Switch On Resistance  
+15V R(ON) VS = +15V, ID = -1mA, VEN = 0.5V  
-5V R(ON) VS = -5V, ID = +1mA, VEN = 0.5V  
+5V R(ON) VS = +5V, ID = -1mA, VEN = 0.5V  
1
1
1
1
+25 C  
50  
50  
50  
-
1000  
4000  
2500  
0.50  
o
+25 C  
o
+25 C  
o
Positive Supply  
Current  
I(+)  
VEN = 0.5V  
+25 C  
mA  
o
Negative Supply  
Current  
I(-)  
VEN = 0.5V  
1
1
1
9
9
+25 C  
-0.50  
-
0.50  
-
mA  
mA  
mA  
ns  
o
Positive Standby  
Supply Current  
+I(SBY)  
-I(SBY)  
TD  
VEN = 4.5V  
+25 C  
-
o
Negative Standby  
Supply Current  
VEN = 4.5V  
+25 C  
-0.50  
o
Make-Before-Break  
Time Delay  
RL = 1000, CL = 50pf  
RL = 10K, CL = 50pf  
+25 C  
5
-
-
o
Propagation Delay  
Times: Address Inputs  
to I/O Channels  
TON (A)  
TOFF (A)  
+25 C  
3000  
ns  
o
Enable to I/O  
TON (EN)  
RL = 1000, CL = 50pf  
9
+25 C  
-
3000  
ns  
TOFF (EN)  
Spec Number 518022  
5