Specifications HS-1840RH
Absolute Maximum Ratings
Reliability Information
Supply Voltage Between Pins 1 and 27 . . . . . . . . . . . . . . . . . . +40V Thermal Resistance . . . . . . . . . . . . . . . . . .
θ
θ
JC
JA
o
o
+VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V
-VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20V
Sidebraze Package . . . . . . . . . . . . . . . . . 83.1 C/W 19.1 C/W
Flatpack Package . . . . . . . . . . . . . . . . . . 49.1 C/W 16.5 C/W
o
o
VREF to Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V Total Power Dissipation (Note)
Analog Input Overvoltage
Sidebraze CerDIP Package. . . . . . . . . . . . . . . . . . . . . . . 1600mW
+VS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+25V (Power On/Off)
-VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25V (Power On/Off)
Digital Input Overvoltage
Ceramic Flatpack Package . . . . . . . . . . . . . . . . . . . . . . . 1400mW
ESD Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
o
o
+VEN, +VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VREF +4V
-VEN, -VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND -4V
Continuous Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mA
NOTE: For DIP Derate 20.4mW/ C above T = +95 C
A
o
o
For Flatpack Derate 18.5mW/ C above T = +95 C
A
o
o
Storage Temperature Range . . . . . . . . . . . . . . . . . -65 C to +150 C
o
Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175 C
Lead Temperature (Soldering 10s). . . . . . . . . . . . . . . . . . . . +275 C
o
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Operating Supply Voltage (±VSUPPLY) . . . . . . . . . . . . . . . . . . . . ±15V Logic Low Level (VAL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.8V
o
o
Operating Temperature Range. . . . . . . . . . . . . . . . -55 C to +125 C Logic High Level (VAH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +4.0V
VREF (Pin 13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5V
TABLE 1. DC ELECTRICAL PERFORMANCE CHARACTERISTICS
Device Guaranteed and 100% Tested. Unless Otherwise Specified: V- = -15V, V+ = +15V, VREF = +5V, VAH = +4.0V, VAL = 0.8V
LIMITS
GROUP A
PARAMETER
SYMBOL
CONDITIONS
SUBGROUPS TEMPERATURE
MIN
MAX
UNITS
o
o
Analog Signal Range
VS
7, 8A, 8B
-55 C, +25 C,
-5
+15
V
o
+125 C
o
o
Input Leakage
Current, Address, or
Enable Pins
IAH
IAL
Measure Inputs Sequentially
Ground All Unused Pins
1, 2, 3
-55 C, +25 C,
-1000 1000
nA
o
+125 C
o
Leakage Current Into
the Source Terminal of
an “Off” Switch
+IS(OFF)
-IS(OFF)
VS = +10V, All Unused Inputs
and Output = -10V, VEN = 4V
1
2, 3
1
+25 C
-10
-100
-10
10
100
10
nA
nA
nA
nA
nA
nA
o
o
+125 C,-55 C
o
VS = -10V, All Unused Inputs,
Output = +10V, VEN = 4V
+25 C
o
o
2, 3
1
+125 C, -55 C
-100
-50
100
50
o
Leakage Current into
the Source Terminal of
an “Off” Switch With
Power “Off”
+IS(OFF)
Power Off
V+, V-, VREF, A0, A1, A2, A3,A4,
EN = GND, Unused Inputs Tied to
GND, VS = +25V
+25 C
o
o
2, 3
+125 C, -55 C
-100
100
o
o
Leakage Current Into
the Source Terminal of
an “Off” Switch With
Overvoltage Applied
+IS(OFF)
VS = +25V, VD = 0V, VEN = 4V
1, 2, 3
1, 2, 3
-55 C, +25 C,
-1000 1000
-1000 1000
nA
nA
o
Overvoltage All Unused Inputs Tied to GND
+125 C
o
o
-IS(OFF) VS = -25V, VD = 0V, VEN = 4V All
Overvoltage Unused Inputs Tied to GND
-55 C, +25 C,
o
+125 C
o
Leakage Current Into
the Drain Terminal of
an “Off” Switch
+ID(OFF)
-ID(OFF)
+ID(OFF)
VD = +10V, VEN = 4V All Unused
Inputs = -10V
1
2, 3
1
+25 C
-10
-100
-10
10
100
10
nA
nA
nA
nA
nA
o
o
+125 C, -55 C
o
VD = -10V, VEN = 4V All Unused
Inputs = +10V
+25 C
o
o
2, 3
1, 2, 3
+125 C, -55 C
-100
100
o
o
Leakage Current Into
the Drain Terminal of
an “Off” Switch With
Overvoltage Applied
VS = +25V, Measure VD,
-55 C, +25 C,
-1000 1000
-1000 1000
o
Overvoltage VEN = 4V, All Unused Inputs to
GND
+125 C
o
o
-ID(OFF)
VS = -25V, Measure VD,
1, 2, 3
-55 C, +25 C,
nA
o
Overvoltage All Unused Inputs to GND
+125 C
Spec Number 518022
3