MBM29LV160TE/BE-70/90/12
• Write (Erase/Program) Operations
Parameter Symbols
JEDEC Standard
Description
70
90
12
Unit
tAVAV
tAVWL
tWLAX
tDVWH
tWHDX
—
tWC
tAS
Write Cycle Time
Address Setup Time
Address Hold Time
Data Setup Time
Data Hold Time
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
70
0
90
0
120
0
ns
ns
ns
ns
ns
ns
ns
ns
ns
tAH
45
35
0
45
45
0
50
50
0
tDS
tDH
tOES
Output Enable Setup Time
0
0
0
Read
0
0
0
Output Enable
—
tOEH
Hold Time
Toggle and Data Polling
10
0
10
0
10
0
tGHWL
tGHEL
tGHWL
tGHEL
Read Recover Time Before Write
Read Recover Time Before Write
(OE High to CE Low)
Min.
0
0
0
ns
tELWL
tWLEL
tWHEH
tEHWH
tWLWH
tELEH
tCS
tWS
tCH
CE Setup Time
Min.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
0
0
0
0
0
0
ns
ns
ns
ns
ns
ns
ns
ns
WE Setup Time
CE Hold Time
0
0
0
tWH
tWP
tCP
WE Hold Time
0
0
0
Write Pulse Width
CE Pulse Width
Write Pulse Width High
CE Pulse Width High
35
35
25
25
8
45
45
25
25
8
50
50
30
30
8
tWHWL
tEHEL
tWPH
tCPH
Byte
tWHWH1
tWHWH1
Programming Operation
Typ.
µs
Word
16
1
16
1
16
1
tWHWH2
—
tWHWH2
tVCS
Sector Erase Operation (Note 1)
VCC Setup Time
Typ.
Min.
Min.
Min.
Min.
Min.
Min.
Min.
s
50
500
4
50
500
4
50
500
4
µs
ns
µs
µs
µs
µs
ns
—
tVIDR
tVLHT
tWPP
tOESP
tCSP
Rise Time to VID (Note 2)
—
Voltage Transition Time (Note 2)
Write Pulse Width (Note 2)
OE Setup Time to WE Active (Note 2)
CE Setup Time to WE Active (Note 2)
Recover Time From RY/BY
—
100
4
100
4
100
4
—
—
4
4
4
—
tRB
0
0
0
(Continued)
31