Errors System  
A switch with transistors is implemented for the pressure sensor voltage source. The MCU sends a signal to the Q2 base. The  
principal voltage source connects to GND and the pressure sensor voltage source is then generated.  
Table 8. Power source  
Source  
+3_3V_D  
Device  
MC9S08LL16L, MAX4734, LMX9838SB, MC9S08JS16, SD Card, buzzer, QS3VH253Q, push buttons.  
(Control or digital section)  
+3_3V_M  
Motor and valve  
+3_3V_PRESS Pressure sensor  
Figure 23. Pressure block on/off power  
11 Errors System  
The system application generates errors in different situations. To prevent any damage in the system and for patient health alerts  
an error is generated. The errors are identied with a number and each number of errors alert about different situations.  
Error(1)Waits a few seconds and if a strip is not detected, the system considers that the strip is used.  
Error(2)Waits a few seconds and if a strip is detected, but does not have a reaction, the system considers that there is  
no blood sample.  
Error(3)Detects a strip and reaction but there is not enough blood to sample.  
Error(4)When the pressure detected is higher than 180 mm Hg it is possible that there is an escape of air.  
Error(5)Heart pulse not detected.  
Error(6)The diastolic pressure is lower than 30 mm Hg.  
Error(7)Bluetooth is enabled but cannot make a connection.  
Error(8)The USB module is enabled but cannot make a connection.  
Error(9)Connection error with the SD Card.  
12 Personal Healthcare Device Class and Medical USB Stack  
Applications  
Personal Healthcare Devices Class (PHDC)It is required to implement methods for sending personal healthcare data to a  
USB host. The PHDC is to enable seamless interoperability between personal healthcare devices and USB hosts.  
Medical USB StackIs based on USB PHDC and the IEEE11073. It is compatible with Continua host emulator software.  
This Medical USB Stack enables microcontrollers with guidelines for Continua Health Alliance connectivity and is a rst step  
to test your application prior ofcial Continua certication.  
Freescale provides implementations to the PHDC using the MC9S08JS16.  
Implementing a Glucometer and Blood Pressure Monitor Medical Devices, Rev. 1, 4/2010  