Table 3-2 Recommended Operating Conditions  
Characteristic  
Symbol  
ΔVSS  
VREF  
TA  
Min  
-0.1  
2.7  
Typ  
Max  
0.1  
Unit  
V
Voltage difference VSS to VSSA  
-
ADC reference voltage  
VDDA  
85  
V
Ambient operating temperature  
–40  
°C  
6
Table 3-3 Thermal Characteristics  
Value  
Characteristic  
Symbol  
Unit  
Notes  
Comments  
160-pin  
LQFP  
160  
MBGA  
Junction to ambient  
Natural convection  
RθJA  
38.5  
63.4  
°C/W  
2
Junction to ambient (@1m/sec)  
RθJMA  
35.4  
33  
60.3  
49.9  
°C/W  
°C/W  
2
Junction to ambient  
Natural convection  
Four layer  
board (2s2p)  
RθJMA  
(2s2p)  
1,2  
Junction to ambient (@1m/sec)  
Four layer  
RθJMA  
31.5  
46.8  
°C/W  
1,2  
board (2s2p)  
Junction to case  
RθJC  
ΨJT  
8.6  
0.8  
8.1  
0.6  
°C/W  
°C/W  
W
3
Junction to center of case  
I/O pin power dissipation  
Power dissipation  
4, 5  
P I/O  
P D  
User Determined  
P D = (IDD x VDD + P I/O  
(TJ - TA) /RθJA  
)
W
Junction to center of case  
PDMAX  
W
7
Notes:  
1. Theta-JA determined on 2s2p test boards is frequently lower than would be observed in an application.  
Determined on 2s2p thermal test board.  
2. Junction to ambient thermal resistance, Theta-JA (RθJA) was simulated to be equivalent to the JEDEC  
specification JESD51-2 in a horizontal configuration in natural convection. Theta-JA was also simulated on  
a thermal test board with two internal planes (2s2p where “s” is the number of signal layers and “p” is the  
number of planes) per JESD51-6 and JESD51-7. The correct name for Theta-JA for forced convection or with  
the non-single layer boards is Theta-JMA.  
3. Junction to case thermal resistance, Theta-JC (RθJC ), was simulated to be equivalent to the measured values  
using the cold plate technique with the cold plate temperature used as the “case” temperature. The basic cold  
plate measurement technique is described by MIL-STD 883D, Method 1012.1. This is the correct thermal  
metric to use to calculate thermal performance when the package is being used with a heat sink.  