FUNCTIONAL DEVICE OPERATION  
LOGIC COMMANDS AND REGISTERS  
Previous Address SOA[2:0]=010  
Previous Address SOA[2:0]=100  
The returned data contain the programmed values in the  
DICR.  
The data in bit OD3 contain the programmed over-current  
high detection level (refer to Table 12), and the data in bits  
OD2, OD1, and OD0 contain the programmed over-current  
low detection levels (refer to Table 11).  
Previous Address SOA[2:0]=101  
• SOA3 = 0. The returned data contain the programmed  
values in the OSDR. Bit OD3 (FSM_HS) reflects the state  
of the output in the Fail-safe mode after a watchdog  
timeout occurs.  
Table 17. Fault Register  
OD7  
x
OD6  
OD5  
OD4  
OD3  
OD2  
UVF  
OD1  
OD0  
OTF OCHF OCLF OLF  
OVF FAULT  
• SOA3 = 1. The returned data contain the programmed  
values in the WDR. Bit OD2 (WDTO) reflects the status of  
the watchdog circuitry. If WDTO bit is Logic [1], the  
watchdog has timed out and the device is in Fail-safe  
mode. If WDTO is Logic [0], the device is in Normal mode  
(assuming device is powered and not in the Sleep mode),  
with the watchdog either enabled or disabled.  
OD7 (x) = Don’t care.  
OD6 (OTF) = Over-temperature Flag.  
OD5 (OCHF) = Over-current High Flag. (This fault is latched.)  
OD4 (OCLF) = Over-current Low Flag. (This fault is latched.)  
OD3 (OLF) = Open Load Flag.  
Previous Address SOA[2:0]=110  
OD2 (UVF) = Under-voltage Flag. (This fault is latched or not  
latched.)  
• SOA3 = 0. OD2, OD1, and OD0 return the state of the IN,  
FSI, and WAKE pins, respectively (Table 18).  
OD1 (OVF) = Over-voltage Flag.  
OD0 (FAULT) = This flag reports a fault and is reset by a read  
operation.  
Table 18. Pin Register  
OD2  
OD1  
OD0  
Note The FS pin reports a fault and is reset by a new Switch-ON  
command (via SPI or direct input IN).  
IN Pin  
FSI Pin  
WAKE Pin  
• SOA3 = 1. The returned data contains the programmed  
values in the UOVR register. Bit OD1 reflects the state of  
the under-voltage protection, while bit OD0 reflects the  
state of the over-voltage protection (refer to Table 16).  
Previous Address SOA[2:0]=011  
The data returned in bits OD1 and OD0 are current values  
for the over-current fault blanking time, illustrated in Table 13.  
Bit OD2 reports when the over-current detection timeout  
feature is active. OD3 reports whether the open load circuitry  
is active.  
Previous Address SOA[2:0]=111  
Null Data. No previous register Read Back command  
received, so bits OD2, OD1, and OD0 are null, or 000.  
33982  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
27  
 复制成功!