FUNCTIONAL DESCRIPTION  
SPI DEFINITION  
SPI DEFINITION  
On each SPI communication, a 16-bit command word is  
sent to the 33879 and a 16-bit status word is received from  
the 33879. The MSB is sent and received first. As Table  
shows, the Command Register defines the position and  
operation the 33879 will perform on rising edge of CS. The  
Fault Register, shown in Table 6, defines the previous state  
status of the output driver. Table identifies the type of fault  
and the method by which the fault is communicated to the  
microprocessor  
Table 6. Command Register Definition  
MSB  
LSB  
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9  
Bit 8  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
ON/  
OFF  
Open Open Open Open Open Open Open  
Load Load Load Load Load Load Load  
Detect Detect Detect Detect Detect Detect Detect Detect  
Open OUT 8 OUT 7 OUT 6 OUT 5 OUT 4 OUT 3 OUT 2 OUT 1  
Load  
8
7
6
5
4
3
2
1
0 = Bits 0 to 7, Output commanded OFF.  
1 = Bits 0 to 7, Output commanded ON.  
0 = Bits 8 to 15, Open Load Detection Current OFF.  
1 = Bits 8 to 15 Open Load Detection Current ON.  
Table 7. Fault Register Definition  
MSB  
LSB  
Bit 0  
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9  
Bit 8  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
0
0
0
0
0
0
0
0
OUT 8 OUT 7 OUT 6 OUT 5 OUT 4 OUT 3 OUT 2 OUT 1  
Status Status Status Status Status Status Status Status  
0 = Bits 0 to 7, No Fault at Output.  
1 = Bits 0 to 7, Output Short-to-Battery, Short-to-GND,  
Open Load, or TLIM  
Bits 8 to 15 will always return “0”.  
.
Table 8. Fault Operation  
Serial Output (DO) Pin Reports  
Over-temperature  
Fault reported by serial output (DO) pin.  
DO pin reports short to battery/supply or over-current condition.  
Not reported.  
Over-current  
Output ON Open Load Fault  
Output OFF Open Load Fault  
DO pin reports output OFF open load condition only with Open Load Detection Current enabled.  
DO pin will report “0” for Output OFF Open Load Fault with Open Load Detection Current disabled.  
Device Shutdowns  
Over-voltage  
Total device shutdown at V  
= VPWR(OV) V. Resumes normal operation with proper voltage. All  
PWR  
outputs assuming the previous state upon recovery from over-voltage.  
Over-temperature  
Only the output experiencing an over-temperature shuts down. Output assumes previous state upon  
recovery from over-temperature.  