ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics
Characteristics noted under conditions 6.0 V ≤ VPWR ≤ 20 V, 3.0 V ≤ VDD ≤ 5.5 V, -40 °C ≤ TA ≤ 125 °C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUTS
Battery Supply Voltage Range
Fully Operational
V
V
PWR
6.0
4.0
–
–
20
28
Extended mode(10)
Battery Clamp Voltage(11)
V
41
47
53
V
PWR(CLAMP)
V
Operating Supply Current
I
mA
PWR
PWR(ON)
Outputs commanded ON, HS[0:3] open, IN[0:3] > V
–
6.5
20
IH
V
PWR Supply Current
I
mA
PWR(SBY)
Outputs commanded OFF, OFF Open-load Detection Disabled, HS[0:3]
shorted to the ground with VDD= 5.5 V WAKE > VIH or RST > VIH and
–
6.5
8.0
IN[0:3] < VIL
Sleep State Supply Current
I
μA
PWR(SLEEP)
VPWR = 12 V, RST = WAKE = IN[0:3] < VIL, HS[0:3] shorted to the ground
TA = 25 °C
TA = 85 °C
–
–
1.0
–
5.0
30
V
V
Supply Voltage
V
3.0
–
5.5
V
DD
DD
DD(ON)
Supply Current at V = 5.5 V
DD
I
mA
DD(ON)
No SPI Communication
–
–
1.6
5.0
2.2
–
8.0 MHz SPI Communication(12)
V
Sleep State Current at V = 5.5 V
I
–
–
5.0
36
μA
V
DD
DD
DD(SLEEP)
Over-voltage Shutdown Threshold
Over-voltage Shutdown Hysteresis
Under-voltage Shutdown Threshold(13)
V
28
32
0.8
3.9
-
PWR(OV)
V
V
0.2
3.3
0.5
3.4
2.2
1.5
4.3
0.9
4.5
2.8
V
PWR(OVHYS)
V
V
PWR(UV)
V
and VDD Power on Reset Threshold
V
PWR
SUPPLY(POR)
Vpwr(UV)_UP
PWR(UV)
V
Recovery Under-voltage Threshold
Supply Failure Threshold ( for VPWR > VPWR(UV)
4.1
2.5
V
)
V
V
DD
DD(FAIL)
Notes
10. In extended mode, the functionality is guaranteed but not the electrical parameters. From 4.0 V to 6.0 V voltage range, the device is only
protected with the thermal shutdown detection.
11. Measured with the outputs open.
12. Typical value guaranteed per design.
13. Output will automatically recover with time limited autoretry to instructed state when VPWR voltage is restored to normal as long as the
VPWR degradation level did not go below the under-voltage power-ON reset threshold. This applies to all internal device logic that is
supplied by VPWR and assumes that the external VDD supply is within specification.
10XS3412
Analog Integrated Circuit Device Data
8
Freescale Semiconductor