ELECTRICAL CHARACTERISTICS  
MAXIMUM RATINGS  
ELECTRICAL CHARACTERISTICS  
MAXIMUM RATINGS  
Table 3. Maximum Ratings  
All voltages are with respect to ground unless otherwise noted. Exceeding these ratings may cause a malfunction or  
permanent damage to the device.  
Ratings  
Symbol  
Value  
Unit  
ELECTRICAL RATINGS  
Supply Voltage Range  
V
V
V
PWR  
PWR(SS)  
Load Dump at 25 °C (400 ms)  
Maximum Operating Voltage  
41  
28  
Reverse Battery at 25 °C (2.0 min.)  
-18  
VDD Supply Voltage Range  
Input/Output Voltage  
VDD  
-0.3 to 5.5  
V
V
(6)  
-0.3 to V +0.3  
DD  
WAKE Input Clamp Current  
CSNS Input Clamp Current  
I
2.5  
2.5  
mA  
mA  
V
CL(WAKE)  
I
CL(CSNS)  
HS [0:3] Voltage  
Positive  
V
HS[0:3]  
41  
Negative  
-16  
Output Current(3)  
I
6
A
mJ  
V
HS[0:3]  
Output Clamp Energy Using Single-pulse Method(4)  
E
100  
CL[0:3]  
ESD Voltage(5)  
Human Body Model (HBM) for HS[0:3], VPWR and GND  
Human Body Model (HBM) for other pins  
Charge Device Model (CDM)  
V
±8000  
±2000  
ESD1  
ESD2  
V
Corner Pins (1, 13, 19, 21)  
V
V
±750  
±500  
ESD3  
ESD4  
All Other Pins (2-12, 14-18, 20, 22-24)  
THERMAL RATINGS  
Operating Temperature  
Ambient  
°C  
°C  
TA  
TJ  
-40 to 125  
-40 to 150  
Junction  
Storage Temperature  
TSTG  
-55 to 150  
Notes  
3. Continuous high side output current rating so long as maximum junction temperature is not exceeded. Calculation of maximum output  
current using package thermal resistance is required.  
4. Active clamp energy using single-pulse method (L = 2.0 mH, R = 0 Ω, V  
= 14 V, T = 150°C initial).  
J
L
PWR  
5. ESD testing is performed in accordance with the Human Body Model (HBM) (CZAP = 100 pF, RZAP = 1500 Ω), the Machine Model (MM)  
(CZAP = 200 pF, RZAP = 0 Ω), and the Charge Device Model (CDM), Robotic (CZAP = 4.0 pF).  
6. Input / Output pins are: IN[0:3], RSTB, FSI, CSNS, SI, SCLK, CSB, SO, FSB  