ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V ≤ VPWR ≤ 20 V, 3.0 V ≤ VDD ≤ 5.5 V, -40 °C ≤ TA ≤ 125 °C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
OUTPUTS HS0 TO HS3 (continued)
Symbol
Min
Typ
Max
Unit
Current Sense Ratio (C
with 28 W bit=1
) Accuracy (6.0 V < V < 20 V)
HS
C
%
SR0
SR0_1_ACC
Output Current
3.0 A
-16
-20
–
–
16
20
1.5 A
C
Current Recopy Accuracy with one calibration point (6.0 V < V
<
HS[0:3]
C
-5.0
–
5.0
%
%/°C
%
SR0
SR0_0_ACC(
CAL)
20 V)(17)
Output Current
5.0 A
C
Current Recopy Temperature Drift (6.0 V < V
< 20 V)
HS[0:3]
Δ(C
)/
SR0
SR0_0
with 28 W bit=0(18)
Output Current
5.0 A
Δ(T)
0.04
Current Sense Ratio (C
with 28 W bit=0
) Accuracy (6.0 V < V
< 20 V)
HS[0:3]
C
SR1
SR1_0_ACC
Output Current
12.5 A
-17
-12
–
–
+17
+12
75 A
Current Sense Clamp Voltage
CSNS Open; I = 5.0 A with C
V
V
CL(CSNS)
ratio
SR0
VDD+0.25
VDD+1.0
HS[0:3]
OFF Open-load Detection Source Current(19)
I
30
2.0
100
–
100
4.0
μA
V
OLD(OFF)
OFF Open-load Fault Detection Voltage Threshold
ON Open-load Fault Detection Current Threshold
V
3.0
300
OLD(THRES)
I
600
mA
mA
OLD(ON)
ON Open-load Fault Detection Current Threshold with LED
I
OLD(ON_LED)
V
= V
- 0.75 V
PWR
2.5
5.0
10
HS[0:3]
Output Short to V
Detection Voltage Threshold
V
V
V
PWR
OSD(THRES)
VCL
Output programmed OFF
V
-1.2
V
-0.8
V
-0.4
PWR
PWR
PWR
Output Negative Clamp Voltage
0.5 A < I
< 5.0 A, Output programmed OFF
-22
155
–
-16
HS[0:3]
Output Over-temperature Shutdown for 4.5 V < VPWR < 28 V
T
175
195
°C
SD
Notes
17. Based on statistical analysis. It is not production tested.
18. Based on statistical data: delta(C
production tested.
)/delta(T)={(measured ICSNS at T1 - measured ICSNS at T2) / measured ICSNS at room} / {T1-T2}. No
SR0
19. Output OFF Open-load Detection Current is the current required to flow through the load for the purpose of detecting the existence of
an open-load condition when the specific output is commanded OFF. Pull-up current is measured for VHS=VOLD(THRES)
10XS3412
Analog Integrated Circuit Device Data
Freescale Semiconductor
11