F75386
6.3 Typical Operating Characteristics
(a) Temperature Error vs.D+/D- Capacitance
Temperature error( ) vs. D+/D- capacitance
℃
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
10 20 30 40 50 60 70 80 90 100 110 120 130
Capacitance(nf)
(b) Local Temperature Error vs. Die Temperature
Local Temperature error( )
℃
3.5
3
2.5
2
1.5
1
0.5
0
-0.5
0
10 20 30 40 50 60 70 80 90 100 110 120
Temperature(
)
℃
(c) Remote Diode Error vs. Remote Temperature Error
Remote Temperature Error
2.5
2
1.5
1
0.5
0
-0.5
-1
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140
Temperature
-5-
F75386
July, 2007
V0.27P