F75386
Remote Temperature High Limit
Monitoring Remote Temperature
F75386 ALERT# pin
Remote High Alert Status
ALERT Mask
End of temperature conversion
ALERT Mask is set and Alert Status is clear
after reading status register
TIME
6.4.3 Alert Response Address mode
If ALERT# is connected to one or more ALERT# outputs of SMBus compatible devices, the master may send an ARA
command to ask that which device is pulling ALERT# to low. When the ALERT# is pulled to low by F75386 and F75386
receives the ARA command sent by the master, F75386 will send its address to the master. The F75386 will reset its
ALERT# output and set the ALERT Mask bit once the master acknowledges its response of device address. The master may
read F75386’s status registers to check what the triggering conditions occur. At the end of interrupt service routine, the
master has to reset ALERT Mask bit in configuration register. Note that the triggering conditions do not include BUSY and
OPEN status in Configuration Register (index 02h). The ARA, 000 1100, is a general call address and is defined in SMBus
specifications. No devices should be assigned to this address.
Remote Temperature High Limit
Monitoring Remote Temperature
F75386 ALERT# pin
Remote High Alert Status
Alert Status is cleared after reading
status register
ALERT Mask
ALERT Mask is set after alerting device
address is transmitted correctly
TIME
-8-