Feature Integration Technology Inc.
Fintek
F75373
6.12
FAN_FAULT/VOLT_FAULT/OVT ENABLE Register Index 35h
Power on default: 00h
Bit Name
Attribute
Description
7
EN_F2_FAULT
R/W
A one enables the fan2 fault status to be indicated in pin
FAN_FUALT.
6
EN_ F1_FAULT
R/W
A one enables the fan1 fault status to be indicated in pin
FAN_FUALT.
5
4
3
EN_T2_OVT
EN_T1_OVT
EN_V3_FAULT
R/W
R/W
R/W
A one enables the VT2 fault status to be indicated in pin OVT.
A one enables the VT1 fault status to be indicated in pin OVT.
A one enables the V3 fault status to be indicated in pin VOLT_FUALT
pin.
2
1
0
EN_V2_FAULT
EN_V1_FAULT
EN_VCC_FAULT
R/W
R/W
R/W
A one enables the V2 fault status to be indicated in pin VOLT
_FUALT.
A one enables the V1 fault status to be indicated in pin VOLT
_FUALT.
A one enables the VCC fault status to be indicated in pin VOLT
_FUALT.
6.13
REAL TIME Fault Status Register 1 Index 36h
Power on default: 00h
Bit Name
Attribute
RO
Description
7
FAN2_FAULT
FAN1_FAULT
VT2_OVT
A one indicates fan2 count limit exceeding.
6
5
RO
A one indicates fan1 count limit exceeding.
RO
This bit will set to 1 from high limit of VT2 is exceeded until the
temperature2 is under the VT2 hysteresis Limit
This bit will set to 1 from high limit of VT1 is exceeded until the
temperature1 is under the VT1 hysteresis Limit
A one indicates a high or low limit of V3 exceeding.
A one indicates a high or low limit of V2 exceeding.
A one indicates a high or low limit of V1 exceeding.
A one indicates a high or low limit of VCC exceeding.
4
VT1_OVT
RO
3
2
1
0
V3_FAULT
V2_FAULT
V1_FAULT
VCC_FAULT
RO
RO
RO
RO
20
V0.25P