Feature Integration Technology Inc.
Fintek
F75373
automatically adjusted according to FAN2 EXPECT register.
01: FAN2 operates in TEMPERATURE mode. PWMOUT2 duty-cycle
is automatically adjusted according to FAN2 EXPECT register, which
will be automatically loaded into preset values according to the
current temperature. (When PIN3 power-on trapped to 1, this mode
is selected after power-on.)
1X: FAN2 operates in MANUAL mode. Software set the PWMOUT2
duty-cycle directly.
5-4
FAN1_MODE
R/W
00: FAN1 operates in SPEED mode. PWMOUT1 duty-cycle is
automatically adjusted according to FAN1 EXPECT register.
01: FAN1 operates in TEMPERATURE mode. PWMOUT1 duty-cycle
is automatically adjusted according to FAN1 EXPECT register, which
will be automatically loaded into preset values according to the
current temperature. (When PIN3 power-on trapped to 1, this mode
is selected after power-on.)
1X: FAN1 operates in MANUAL mode. Software set the PWMOUT1
duty-cycle directly.
3
2
Reserved
KEEP_DROP_DU
R/W
Set to 1, keep PWMOUT2 duty-cycle decrease to DROP duty and
hold.
TY2
1
0
KEEP_DROP_DU
R/W
Set to 1, keep PWMOUT1 duty-cycle decrease to DROP duty and
hold.
TY1
EN_RESET_TIME
R
R/W
Set to 1, enable interface_idle timer. Set to 0, disable the timer.
When the timer is enabled, if software doesn’t access the this chip
through GP_CLK and GP_DATA, the reset timer starts to count down
according to the value set in INDEX 62H. When it counts down to
zero, INDEX[72H, 73H] will be loaded into INDEX[74H,75H].
6.19
Fan Fault Time Register -- Index 61h
Power on default: B4h
Bit Name
7-0 F_FAULT_TIME
Attribute
Description
This register determines the time of fan fault. Two conditions cause
fan fault event:
R/W
22
V0.25P