F71869A
87h
R/W
R
46h
--
Temperature sensor 3 high limit. The unit is 1ºC.
88-8Bh
8C~8Dh
Reserved
Reserved
R
FFH
6.6.49 Temperature Filter Select Register ⎯Index 8Eh
Bit
Name
R/W Default
Description
The queue time for second filter to quickly update values.
00: 8 times.
7-6
IIR-QUEUR3
R/W
R/W
R/W
1h
1h
1h
01: 12 times.
10: 16 times. (default)
11: 24 times.
The queue time for second filter to quickly update values.
00: 8 times.
5-4
3-2
IIR-QUEUR2
IIR-QUEUR1
01: 12 times.
10: 16 times. (default)
11: 24 times.
The queue time for second filter to quickly update values.
00: 8 timers.
01: 12 times.
10: 16 times. (default)
11: 24 times.
The queue time for second filter to quickly update values. (for CPU
temperature from PECI or TSI interface)
00: 8 timers.
1-0 IIR-QUEUR_DIG R/W
1h
01: 12 times.
10: 16 times. (default)
11: 24 times.
Fan Control Setting
6.6.50 FAN PME# Enable Register ⎯ Index 90h
Bit
Name
R/W Default
Description
7-3
Reserved
R
0
Reserved
A one enables the corresponding interrupt status bit for PME#
interrupt
2
EN_FAN3_PME R/W
0
Set this bit 1 to enable PME# function for Fan3.
85
Oct., 2011