欢迎访问ic37.com |
会员登录 免费注册
发布采购

F71869AD 参数 Datasheet PDF下载

F71869AD图片预览
型号: F71869AD
PDF下载: 下载PDF文件 查看货源
内容描述: 超级I / O +硬件监控 [Super I/O + Hardware Monitor]
分类和应用: 监控
文件页数/大小: 156 页 / 1561 K
品牌: FINTEK [ FEATURE INTEGRATION TECHNOLOGY INC. ]
 浏览型号F71869AD的Datasheet PDF文件第10页浏览型号F71869AD的Datasheet PDF文件第11页浏览型号F71869AD的Datasheet PDF文件第12页浏览型号F71869AD的Datasheet PDF文件第13页浏览型号F71869AD的Datasheet PDF文件第15页浏览型号F71869AD的Datasheet PDF文件第16页浏览型号F71869AD的Datasheet PDF文件第17页浏览型号F71869AD的Datasheet PDF文件第18页  
F71869A  
FANCTL3 (Suppot scan code setting).  
Diskette change. This signal is active low at power on and  
whenever the diskette is removed.  
DSKCHG#  
INst,5v  
FDC function is selected by register setting.  
4.4 UART and SIR  
Pin No.  
Pin Name  
Type  
PWR  
Description  
Default General Purpose IO.  
GPIO42  
I/OOD12t,5v  
27  
3VCC  
Infrared Transmitter Output. The function is selected by  
register setting.  
IRTX  
GPIO43  
IRRX  
O12  
I/OOD12t,5v  
INst,5v  
Default General Purpose IO.  
28  
3VCC  
Infrared Receiver input. The function is selected by register  
setting.  
Data Carrier Detect. An active low signal indicates the  
modem or data set has detected a data carrier.  
Ring Indicator. An active low signal indicates that a ring  
signal is being received from the modem or data set.  
118  
DCD1#  
INst,5v  
3VCC  
119  
120  
RI1#  
INst,5v  
INst,5v  
I_VSB3V  
CTS1#  
3VCC Clear To Send is the modem control input.  
UART 1 Data Terminal Ready. An active low signal informs  
the modem or data set that controller is ready to  
communicate. Internal 47k ohms pulled high and disable  
after power on strapping.  
DTR1#  
O8t5v,u47k  
121  
3VCC  
Power on strapping pin:  
1(Default): (Internal pull high)  
FAN40_100  
RTS1#  
INt,5v  
Power on fan speed default duty is 40%.(PWM)  
0: (External pull down)  
Power on fan speed default duty is 100%.(PWM)  
UART 1 Request To Send. An active low signal informs the  
O8t5v-u47k  
modem or data set that the controller is ready to send data.  
Power on Strapping pin for over voltage protection function.  
1: Default is alarm mode (disabled). Voltage protection  
function is enabled via setting the related register.  
122  
123  
3VCC  
STRAP_PROT  
ECT  
INt,5v  
0: Force mode which is always enabled after power on.  
Data Set Ready. An active low signal indicates the modem  
DSR1#  
SOUT1  
INst,5v  
3VCC or data set is ready to establish a communication link and  
transfer data to the UART.  
UART 1 Serial Output. Used to transmit serial data out to  
the communication link. Internal 47k ohms pulled high and  
disable after power on strapping.  
O8t5v,u47k  
124  
3VCC  
Power on strapping:  
STRAP4E_2E  
INt,5v  
1(Default): Configuration register 4E  
0: Configuration register 2E  
Serial Input. Used to receive serial data through the  
125  
126  
SIN1  
INst,5v  
INst,5v  
3VCC  
communication link.  
Data Carrier Detect. An active low signal indicates the  
3VCC  
DCD2#  
modem or data set has detected a data carrier.  
14  
Oct., 2011  
V0.19P