AT commands
Serial interfacing commands
Parameter
Description
1200 b/s
2400 b/s
4800 b/s
9600 b/s
19200 b/s
38400 b/s
57600
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
0x8
115200 b/s
230400 b/s
Default
0x03 (9600 b/s)
NB (Parity)
This command applies to the XBee/XBee-PRO S2C 802.15.4 RF Module.
Set or read the serial parity settings for UART communications.
The device does not actually calculate and check the parity. It only interfaces with devices at the
configured parity and stop bit settings.
Parameter range
0x00 - 0x04
Parameter
0x00
Description
No parity
0x01
Even parity
0x02
Odd parity
Mark parity (forced high)
0x03
Default
0x00
RO (Packetization Timeout)
This command applies to the XBee/XBee-PRO S2C 802.15.4 RF Module.
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode. RF transmission will also commence when the maximum
payload (see Maximum payload) is received in the DI buffer.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
88